Product code RXSOL-51-5005-210Category Evaporator Treat

Price and availability on request. Send us the quantity and delivery location in Oman.

Condensate Amine Neutralizer Corrosion Inhibitor supplier and manufacturer in Oman

In short: Condensate Amine Neutralizer Corrosion Inhibitor is our concentrated liquid RXSOL treatment for steam and condensate corrosion control. We manufacture and supply it for boiler feedwater, steam lines and condensate return systems. We are the largest Condensate Amine Neutralizer Corrosion Inhibitor supplier in Oman and keep it in stock at our Barka warehouse. It is available in 25 L cans, 210 L drums and 1000 L IBCs for delivery to Muscat, Sohar, Salalah and Duqm. Send us your quantity on WhatsApp for today's price.

Why use a condensate amine neutralizer in a steam plant?

Carbon dioxide dissolves in steam condensate and forms carbonic acid. The acid lowers condensate pH and can corrode carbon steel return lines. Corrosion carries iron through the system and can eventually cause leaks.

Our water-soluble blend contains diethylaminoethanol (DEAE) and morpholine. These neutralizing amines travel with the steam and help control acidity as it condenses. Their different steam and condensate distribution characteristics help treatment reach different parts of the system.

Look at your condensate readings and return lines when:

  • Condensate pH falls below your plant's specified range, especially at remote return points.
  • Iron readings rise in the condensate or feedwater.
  • Return pipes show corrosion or develop leaks.
  • Make-up water or operating conditions change and treatment demand may have changed.

These signs need investigation. Low pH is one cause of corrosion, but oxygen and other system conditions can also contribute.

Which condensate treatment approach suits your system?

Your situationWhat to do
Acidic condensate across a steam networkUse the DEAE and morpholine blend to raise condensate pH and reduce carbonic acid corrosion.
Remote returns show lower pH than the main returnSample those returns as well as the main outlet. Adjust treatment using the results and the system's distribution.
Copper alloys are presentSet the pH range for the system metallurgy and equipment specifications. Monitor copper as well as iron.
Steam contacts food or other regulated productsEstablish whether the amines and finished product are permitted for the actual steam use before dosing.

The blend suits compatible industrial steam systems, including power generation, refinery, petrochemical and manufacturing plants. Boiler pressure, materials and steam use all matter when setting the treatment programme.

Step by step: dosing RXSOL condensate amine

  1. Choose a suitable feedwater or condensate injection point and connect a calibrated chemical dosing pump.
  2. Set the plant's condensate pH target with the water treatment specialist, taking account of metallurgy and equipment limits.
  3. Establish the initial feed rate from condensate pH, carbon dioxide loading, feedwater quality and steam distribution.
  4. Dose continuously for steady control. Take representative samples from the main return and remote condensate points.
  5. Measure pH, iron, copper and treatment residuals. Adjust the pump rate using the results and record the readings.

A typical condensate pH range in our product information is 8.5 to 9.2. It also lists other ranges, so this is not a universal set point. The right range depends on the system, particularly where copper alloys are present.

The product information gives an example dose of about 0.65 L per day for a 10 m³ system. Operating conditions are not specified for that example, so use testing to establish your own feed rate. If dilution is needed, use condensate or demineralised water only when compatible with the dosing arrangement and treatment instructions.

Mistakes to avoid with steam condensate treatment

  • Keeping the same pump setting after conditions change. Changes in make-up water, carbon dioxide loading or steam use can change the amount of amine needed.
  • Testing only one return point. Amines and carbon dioxide do not necessarily distribute evenly. A satisfactory main return reading can hide a low pH elsewhere.
  • Feeding more amine to deal with oxygen corrosion. Neutralizing amines control acidity. They do not protect against oxygen attack on their own; deaeration and a compatible oxygen-control programme may also be needed.
  • Assuming the blend forms a protective film. Treat it as a neutralizing amine unless the finished product's filming performance has been verified.
  • Setting pH without considering copper alloys. An unsuitable target can create problems for copper-containing equipment.

Safety, storage and MSDS

The liquid is alkaline and its vapours can irritate the eyes and lungs. Avoid breathing vapour and contact with skin and eyes. Wear chemical-resistant gloves, protective clothing and eye or face protection, and provide good ventilation.

Keep the container tightly closed in a cool, ventilated area, away from excessive heat and incompatible chemicals. For handling and exposure instructions, press "Get MSDS" at the top of this page. Finished-blend properties such as flash point and active concentration require verification; request the applicable product documentation with your order.

Condensate Amine Neutralizer Corrosion Inhibitor or another product?

  • Carbonic acid in steam and condensate: Use our RXSOL condensate amine to control pH through the steam and return network.
  • Oxygen control: Consider Corroision Inhibitor for Oxygen Control as part of a compatible oxygen-control programme.
  • Hardness entering the boiler: Hardness Control Boiler Treatment addresses a different part of the water treatment programme.
  • Water for a compatible dosing dilution: Demineralised Water is an option where the treatment instructions permit dilution.

Condensate Amine Neutralizer Corrosion Inhibitor price and quotation in Oman

We stock 25 L cans, 210 L drums and 1000 L IBCs at Barka. The price depends on pack, quantity and delivery point. To buy, send your quantity, pack and location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers get volume prices. We deliver from Barka to Muscat, Sohar, Salalah and Duqm.

Overview

Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2

Product description

RXSOL Neutralizing Amine – Steam & Condensate Corrosion Inhibitor

Product Type: DEAE and Morpholine-Based Neutralizing Amine Application: Boiler Feedwater, Steam and Condensate Systems Function: pH Adjustment and Corrosion Protection

Product Description

RXSOL Neutralizing Amine is a concentrated, water-soluble chemical treatment formulated with Diethylaminoethanol (DEAE) and Morpholine for pH adjustment and corrosion protection in boiler feedwater, steam distribution and condensate return systems.

The product is designed to neutralize carbonic acid formed when carbon dioxide dissolves in steam condensate. By maintaining the appropriate pH, it helps reduce acid-related corrosion of carbon steel piping, condensate lines and associated equipment.

The combination of DEAE and Morpholine provides complementary steam/condensate distribution characteristics, supporting corrosion protection across different sections of the system.

RXSOL-51-5005-210  Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2 throughout a condensate system. Protects boiler surfaces by forming an iron tannate film.
A liquid neutralizing amine used to control corrosion and pH in steam and condensate systems.

Applications

Applications

Boiler Feedwater Treatment: Used for pH adjustment and control of acidic conditions in compatible boiler feedwater systems.

Steam Distribution Networks: Helps protect piping and associated equipment against carbonic acid corrosion.

Condensate Return Systems: Maintains suitable condensate pH to reduce corrosion and iron contamination.

 

Industrial Steam Plants: Applicable to power generation, petrochemical, refinery and manufacturing steam systems, subject to system-specific treatment requirements.

 

RXSOL-50-5005-025 is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the complete system.The most common cause of acid corrosion in condensate and feed water systems is dissolved carbon dioxide. Condensate control neutralises this acid and maintains the condensate and feed water in an alkaline condition
Used in medium and high-pressure boilers including ultra high-pressure boilers.

Fields Of Application:-
RXSOL-50-5005-025 is an effective neutralizing type corrosion inhibitor & oxygen scavanger  for steam condensation system. And can also be used to protect Boilers /Metals surfaces form corrosion.It removes oxygen efficiently in open feed systems and gives effective corrosion inhibition of boiler/exhaust gas economizer system surfaces . Its Chemical reaction by converting Fe2O3 (rust) to organic iron compound protect further IRON rust reaction .

Operating Process:-
RXSOL-CC72 neutralizes the acid components of feed water.The proportion of RXSOL-50-5005-025 depends upon the Carbon dioxide content of the condensate. Basically RXSOL-50-5005-025 neutralizes the acid contents & maintains the condensate and feed water in the alkaline condition.  It also protects copper based metals.

PRODUCT APPLICATION
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.

Industries and related products

Protection of Condenser from Corrosion in Boiler / Power plant.

Condenser  and its related accessory like condensate pump protection from corrosion is important task to avoid high maintenance cost due to acidic cavitation which can cause plant unplanned downtime. Unnecessary condenser maintenance also effect production yield.

What is condenser?

Condenser helps to condensate high temperature steam to water which can be collected and returned to further utilize in the steam generator. During condensation condensate control works during super heated temperature steam to neutralize or prohibit acid formation which is causes of cavitation and rusting etc...

Benefit of uses of Condensate Control - Condensnol amine?

Save maintenance cost
Avoid down time of system.

Increase production yield.
Acidic medium causes rust / cavitaion which is resulting more vibration of motor plant machiner, Condensnol Amine uses effectively neutralizes Acid during condensation.

Dosage

Recommended Dosing Procedure

Inject the neutralizing amine into a suitable feedwater or condensate treatment injection point using a calibrated chemical dosing pump.

The dosage should be established from condensate pH, carbon dioxide loading, feedwater quality, steam distribution characteristics and operating conditions.

A typical condensate pH target may be approximately 8.5–9.2, but the correct range depends on system metallurgy, particularly the presence of copper alloys, and the applicable equipment specifications.

 

Monitor condensate pH, iron and copper concentrations, and treatment residuals to optimize dosing.

 

RXSOL-51-5005-210 condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.65 ltr / day .

The necessary amount of RXSOL-51-5005-210 is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 .  The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.

Also known as

NEUTRALIZING AMINE Corrosion Inhibitor for Condensate Treatment and Control 210 Ltr

Notes

Key Features & Benefits

  • Neutralizes carbonic acid in steam condensate.

  • Adjusts and maintains condensate pH within the required operating range.

  • Helps protect boiler feedwater and condensate return pipelines against acid corrosion.

  • Combines DEAE and Morpholine for broader system distribution.

  • Water-soluble liquid suitable for controlled chemical injection.

  • Designed for continuous dosing into appropriate feedwater circuits.

  • Helps reduce iron transport associated with condensate corrosion.

  • Supports reliable operation of industrial steam systems.

  • Easy to use liquid treatment.
  • Neutralizes the acids occurring in the condensate system.
  • Less maintenance required. Lower operating costs and increased reliability.
  • Volatilizes and carries over with the steam and so is recycled. Dosage is economical and efficient.
  • Simple test to determine level of treatment.
  • Used for protection of condensate and feed water systems in boiler systems of all pressures.

Remarks

Important Formulation Considerations

The specified DEAE and Morpholine ranges allow a combined active concentration above 22%, but the selected formulation must actually meet that requirement.

Two other specifications require particular attention:

Flash Point Above 90°C: This must be verified by closed-cup testing of the finished blend. The presence of DEAE can materially affect flash point, and an aqueous formulation should not be assumed to meet this limit without testing.

Vapour Pressure 0.5 mmHg at 37.8°C: This also requires verification on the finished formulation because the individual amines and water contribute to the blend's vapour pressure.

The chloride and sulphate limits are very low and should be confirmed using appropriate analytical methods and high-purity raw materials.

Storage & Handling

Store in tightly closed, chemically compatible containers in a cool, ventilated area. Protect against contamination, excessive heat and incompatible chemicals.

Use appropriate gloves, protective clothing and eye/face protection. Consult the finished-product SDS before handling.

Regulatory note: DEAE and Morpholine use in steam systems may be restricted by steam end use, especially where steam can contact food or other regulated products.

 

RXSOL CHEMO PHARMA INTERNATIONAL Product: Neutralizing Amine for Steam & Condensate Systems Chemical Base: DEAE + Morpholine Website: www.rxmarine.com

 

Formulation note: Before issuing a final TDS or COA, the active concentration, flash point, vapour pressure, chloride, sulphate and shelf-life specifications should be validated on the actual manufactured blend.

 

RXSOL-51-5005-210 alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.

Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.

Packing. GENERAL REMARKS:-Do not store  RXSOL-51-5005-210  near a heating equipment.

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.

Questions about Condensate Amine Neutralizer Corrosion Inhibitor

Who is the largest Condensate Amine Neutralizer Corrosion Inhibitor supplier in Oman?

Oman Chem is the largest Condensate Amine Neutralizer Corrosion Inhibitor supplier in Oman. We manufacture our own RXSOL formulation and stock it at our Barka warehouse.

What does a neutralizing amine do in a boiler system?

It travels with steam and neutralizes carbonic acid in the condensate. This raises pH and helps reduce acid corrosion in return piping and associated equipment.

How much condensate amine should I dose?

The feed rate depends on carbon dioxide loading, water quality, steam distribution and operating conditions. Use representative condensate tests to establish and adjust the dose.

Can this RXSOL condensate treatment be used with copper alloys?

Copper alloys must be considered when selecting the condensate pH range. Monitor copper concentrations and use the equipment supplier's limits for the system.

Does this neutralizing amine replace an oxygen scavenger?

No. Neutralizing amines address acidic conditions but do not protect against oxygen attack on their own. The system may also need deaeration and a compatible oxygen-control programme.

What is the price of Condensate Amine Neutralizer Corrosion Inhibitor in Oman?

We quote each order by pack, quantity and delivery point. Send your requirement on WhatsApp or through the quote form for today's price.