Product Code ::RXSOL-50-5004-025
Product Short Description: A well-balanced premium grade water treatment blend of several powder for boiler water treatment, resulting in a scale and corrosion control by one simple operation.
Product Description:

RXSOL-50-5004-025 is a dry powder containing Alkalinity builders, Phosphates and Sludge Conditioners.

RXSOL-50-5004-025  is a well-balanced blend of several powder for boiler water treatment, resulting in a scale and corrosion control by one simple operation.

Product Application:

The correct level of alkalinity ensures that optimum conditions exist for :
Precipitation of hardness salts in conjunction with phosphate.
Neutralization of acidic conditions. Avoidance of caustic corrosion.
Control of magnesium and calcium salts.
Control of hardness.
RXSOL-50-5004-025  provides a phosphate reserve to effectively react with and precipitate the hardness salts introduced with the feed water.

selected BOILER COMPOUND FOR LOW PRESSURE STEAM BOILER.

Product Dose:

RXSOL-50-5004-025 is best dosed by means of a bypass pot feeder directly into the boiler feed line

Funtion Mechanism:-

Alkalinity Control:-This components of  RXSOL-50-5004-025  chemically  precipitate  the hardness of salts like Calcium & Magnesium & neutralizes the acidic conditions.
Hardness Control:-RXSOL-50-5004-025 provides phosphate reserve  to effectively  react with  and precipitate the hardness salts introduces with the feed water.
Sludge Conditioner:-RXSOL-50-5004-025 component  will preventing the sludge from  adhering to metals surfaces. Boiler sludge can only be removed by blow down.
Oxygen Scavanger:-Catalyzed  of  RXSOL-50-5004-025  controls  the formation of  oxygen to protects boiler & steam line corrosion protection. As an  additional benefits it will assist to neutralize dissolved carbon dioxide. In this way  RXSOL-50-5004-025  preventing oxygen “Pitting” corrosion.

Applications, Dosage:-RXSOL-50-5004-025 is strongly alkaline. RXSOL-50-5004-025  is best applied diluted with WATER ,  any convenient  strength on a continuous  basis using a  suitable chemicals pump . The product  should be applied to the boiler feed tank or feed line to ensure adequate  mixing. The dosage rate of   RXSOL-50-5004-025  is dependent on boiler operating condition, Feed 1 Kg  of RXSOL-50-5004-025 solution for per thousand Ltr of boilers water Then control  the  system by  Periodic Alkalinity  test procedure.  If p-Alkalinity is below 200  ppm  increase the  ratio of  RXSOL-50-5004-025   solution. If  p-Alkalinity  is above  400 ppm  reduce  the  concentration of 
RXSOL-50-5004-COMB solution by dilution with water.
           
Control Procedure:-Control is by simple  boiler water tests or RX CLEANSERS  can provide a suitable test  kits for this purpose
 

Product Note:

Characteristics:-

• Convenient treatment, which provides the basic alkalinity on which successful water treatment depends.
• Provides optimum conditions for hardness control to function.
• Neutralizes acid conditions.
• Will assist in keeping silica in suspension.
• Simple test to determine level of treatment.
• Can be used in boilers of all pressures.
• Can be used as a neutralizer after acid cleaning operations
• Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.
• Dispersant action suspends sludge and sediment particles for efficient blow down.
• Oxygen scavenging for optimum protection.
• Protects boiler, steam lines, condensate lines and feed water lines from corrosion .
• Fast action due to catalyst .
• Simple test to determine level of treatment .

Packaging, Handling, First Aid & Storage:-RXSOL-50-5004-025  is generally supplied in drums containing 25 Kg/50 Kg barrel . Avoid contact with skin and eyes wear goggles & PVC gloves when handling. Keep an eye wash bottle close to the point of use. Do not take internally.On contact with Skin/Cloth, wash immediately with cupious amount of water. If eyes are affected they should be washed with water for at least 15 Minutes and medical attention sought immediately. If swallowed do not induces vomiting give plenty of water and call doctor immediately.
                                               

                                                                    **Keep drums tightly closed when not in use.**

Remarks:
Product Tag Identification:
Product Useful Area:

Keyword:

Boiler Water Treatement chemicals compound

packaing_size:

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates