RXSOL-16-1047-210 corrosion Inhibitor is an organic, liquid, cationic corrosion inhibitor especially designed to inhibit the attack of hydrochloric acid and steel during industrial cleaning operations. It also inhibits acid attack on copper and brass. It does not contain arsenic, chlorinated hydrocarbons, or lead compounds.
Acid corrosion Inhibitor RXSOL-16-1047-210 inhibitors meet the requirements of Military Specification Nos.MIL-I-17433 and MIL-C-17434.
1 gallon for a cleaning temperature of 150° Fahrenheit.
2 gallons for a cleaning temperature of 175° Fahrenheit.
3 gallons for a cleaning temperature of 200° Fahrenheit.
* A 5% by weight hydrochloric acid solution contains 14.1% by volume of 20° hydrochloric acid.
The exceptional strength and heat stability of Acid corrosion Inhibitor RXSOL-16-1047-210 give the user a considerable safety factor in relation to temperature, acid strength, and time. Acid corrosion Inhibitor RXSOL-16-1047-210 may be added to either the diluted or concentrated hydrochloric acid. In either case, Acid corrosion Inhibitor RXSOL-16-1047-210 should be thoroughly mixed with the acid by stirring or agitation.
The hydrochloric acid solution inhibited with Acid corrosion Inhibitor RXSOL-16-1047-210 is best circulated through the equipment to be cleaned. When circulation cannot be accomplished, the equipment should be filled with the inhibited acid and allowed to react for sufficient time to remove the objectionable deposits. To estimate the proper acid concentration and cleaning time, samples of the deposits to be removed can be tested in the laboratory prior to cleaning. If heating of the equipment to be cleaned or acid solution is desired to speed the cleaning action, it should be done prior to the start of the cleaning operation.
Acid corrosion Inhibitor RXSOL-16-1047-210 and will not freeze at temperature as low as -20° Fahrenheit. Below 0° Fahrenheit,Acid corrosion Inhibitor RXSOL-16-1047-210 become very viscous and may be difficult to pump. It is recommended that Acid corrosion Inhibitor RXSOL-16-1047-210 be stored in a dry area where the temperature will not go lower than 0° Fahrenheit.
Applicable regulations concerning disposal and discharge of chemicals should be consulted and followed-
Disposal information for Acid corrosion Inhibitor RXSOL-16-1047-210 is given on the Material Safety Data Sheet for each product.The industrial cleaning bath is acidic and contains hydrochloric acid and organic Acid corrosion Inhibitor RXSOL-16-1047-210 components. Waste treatment , neutralization is required. The industrial cleaning bath and sludge can contain ingredients other than those in the chemical as supplied and analysis of the solution and/or sludge is required before waste treatment and disposal.
38249022
NALCO EC1304A, Cationic corrosion inhibitor designed to inhibit the attack of hydrochloric acid. Acid Corrosion Inhibitor
NALCO EC1304A, Cationic corrosion inhibitor designed to inhibit the attack of hydrochloric acid. Acid Corrosion Inhibitor
Corrosion inhibitor especially designed to inhibit the attack of hydrochloric acid on iron and steel during industrial cleaning operations. It also inhibits acid attack on copper and brass. It does not contain arsenic, chlorinated hydrocarbons, or lead compounds.
Corrosion Inhibitor manufacturer and supplier in Mumbai, Gandhidham, Vizag - Visakhapatnam, Chennai, Kolkata, Fujairah, Dubai, Sharjah, Ajman, Abudhabi, Muscat - Oman.