Product code RXSOL-43-4023-020Category Cooling Water Chemical

Price and availability on request. Send us the quantity and delivery location in Oman.

CorroSOL 40 Nitrite Corrosion Inhibitor supplier and manufacturer in Oman

In short: CorroSOL 40 is our own RXSOL nitrite-borate corrosion inhibitor for closed water circuits. It protects steel, cast iron, copper and brass in chilled water loops, low temperature hot water (LTHW) heating, glycol brine and engine jacket cooling. We manufacture it and keep it in stock at our Barka warehouse, and we are the largest CorroSOL 40 Nitrite Corrosion Inhibitor supplier in Oman. We deliver to Muscat, Sohar, Salalah and Duqm in 25 L cans, 210 L drums and 1000 L IBCs. Send us your quantity on WhatsApp or through the quote form for today's price.

When does a closed loop need a corrosion inhibitor?

Untreated closed circuit water slowly attacks the system from the inside. Dissolved oxygen turns iron into rust. The damage usually shows up as:

  • Leaks at plate heat exchangers (PHE) and AHU coils.
  • Brown or cloudy water at drain points and strainers.
  • Plugged tubes and a falling flow rate.
  • Poor heat transfer, so the chiller or boiler works harder for the same duty.
  • Regular descaling shutdowns that cost labour and time.

A newly filled loop, a loop topped up with a lot of make-up water, or a loop with a falling nitrite reading all need a dose. CorroSOL 40 is a strong passivator of exposed or corroded metal. Its organic inhibitor protects the copper and brass parts, and its antiscalant helps keep heat transfer surfaces clean.

Closed loop corrosion inhibitor dose for chilled water, LTHW and engine cooling

Your systemSuits CorroSOL 40?Dose
Closed chilled water circuit (chillers, AHU, FCU, PHE)Yes, steel and copper pipework7 L per 1000 L of system water at first fill
LTHW and low pressure heating circuitsYes7 L per 1000 L at first fill
Glycol brine and process chilling or heatingYes, steel and copper loops7 L per 1000 L at first fill
Engine jacket cooling and engine coolantYes, when the circuit has no aluminium parts7 L per 1000 L at first fill
Top up after draining or a large water lossAll of the above5 to 7 L per 1000 L
Any loop with aluminium or galvanised pipeworkNoUse an inhibitor made for these metals, such as our Corrosion Inhibitor Antifoulant for Aluminium cooling system

The first dose of 7 L per 1000 L should give a nitrite reserve of at least 1200 mg/l. After that, the test kit result tells you when to add more.

What the CorroSOL 40 name, form and category mean for you

  • Nitrite-borate base with an organic inhibitor. The nitrite protects steel and cast iron, the borate buffers the water pH, and the organic inhibitor covers copper and brass. One product treats a mixed-metal loop.
  • Liquid concentrate. Specific gravity about 1.1, pH about 12, fully soluble in water. It goes straight into the loop through a dosing pump or the expansion tank, with no dissolving step.
  • Corroban 40 alternative in Oman. CorroSOL 40 is also listed as Corroban 40 Nitrite Corrosion Inhibitor. If your maintenance plan or an old drum label says Corroban 40, order CorroSOL 40.
  • Cooling water chemical range. It sits in our cooling water treatment range, so the biocide and other treatments for the same loop can come in one delivery from Barka.

Step by step: dosing a closed chilled water loop

  1. Work out the system water volume, including pipework, chiller barrels and buffer vessels.
  2. Check that the loop has no aluminium or galvanised parts.
  3. Put on chemical goggles and chemical-resistant gloves.
  4. Add 7 L of CorroSOL 40 for every 1000 L of system water, by injection dosing pump or through the expansion tank.
  5. Circulate until the inhibitor reaches every branch and dead leg.
  6. Take a sample and test it with a nitrite closed system test kit. Aim for at least 1200 mg/l.
  7. Log the reading. Test again at regular intervals and after any drain down, and add 5 to 7 L per 1000 L when the reserve falls.

Mistakes to avoid

  • Dosing a loop with aluminium or galvanised pipework. CorroSOL 40 is not meant for these metals.
  • Dosing once and never testing. When nitrite falls too low, the risk of local pitting goes up. A part-treated loop is not a protected loop.
  • Blaming a leak every time nitrite drops. Bacteria also consume nitrite. If the reading falls but water loss is small, treat the loop with BIOCIDE for Closed Loop Chilled Water.
  • Expecting the inhibitor to clean a dirty loop. Heavy rust, sludge and leaks need cleaning and repair first. Flush a new system with a pre-commissioning cleaner such as Commissioning Cleaner before the first dose.
  • Using the closed loop dose in an open cooling tower. CorroSOL 40 is made for closed recirculating circuits.

Safety, storage and MSDS

Avoid contact with skin and eyes and do not breathe the mist. Wear goggles, gloves and overalls, and keep plant rooms well ventilated while dosing. Store containers tightly closed in a cool, shaded and ventilated place, away from acids, ammonium salts, combustible materials, heat and food. Keep spills out of drains and waterways.

Read the MSDS before use: press "Get MSDS" at the top of this page to request it.

CorroSOL 40 Nitrite Corrosion Inhibitor or another product?

  • Steel and copper closed loops, chilled water, LTHW, glycol brine and engine jacket circuits: CorroSOL 40.
  • You prefer a molybdate programme for your closed loop: CorroSOL 50 Molybdate Corrosion Inhibitor.
  • Diesel engine cooling water on ships and gensets: Engine Water Treatment DEWT.
  • Not sure which fits: send us the system volume, the metals in the loop and your last water test, and we tell you which treatment to use.

CorroSOL 40 Nitrite Corrosion Inhibitor price and quotation in Oman

The price of CorroSOL 40 depends on the pack, the quantity and the delivery point, so we quote every order. Send us the quantity, the pack (25 L can, 210 L drum or 1000 L IBC) and the delivery location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers and contractors get volume prices. We deliver from Barka to Muscat, Sohar, Salalah, Duqm and to ships at Port Sultan Qaboos, Sohar Port, Salalah Port and Duqm.

Overview

Nitrite based corrosion inhibitor for excellent protection for chilled water, LTHW systems

Product description

Nitrite based corrosion inhibitor for excellent protection for chilled water, LTHW systems. CorroSOL 40 Nitrite Corrosion Inhibitor is a nitrite-borate based corrosion inhibitor containing an additional organic inhibitor to protect steel, copper and other non-ferrous metals. As such CorroSOL 40 Nitrite Corrosion Inhibitor is an ideal treatment for closed chilled water and low pressure heating systems.

Applications

CorroSOL 40 Nitrite Corrosion Inhibitor is an extremely strong passivator of exposed or corroded metal surfaces.
CorroSOL 40 Nitrite Corrosion Inhibitor is NOT intended for use in systems containing Aluminium or galvanised pipework.
Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant,Process chilling and heating system etc.
 

Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant,Process chilling and heating system etc.

 

Where it is used

How to use CorroSOL 40 Nitrite Corrosion Inhibitor
CorroSOL 40 Nitrite Corrosion Inhibitor should be added to the system at an initial dosage rate of 7 litres / 1000 litres of system water content. This will passivate metal and should establish the required minimum Nitrite reserve of 1200mg/l. Whenever the system is drained or loses a significant quantity of water then the additional CorroSOL 40 Nitrite Corrosion Inhibitor should be added at the rate of 5 – 7 litres / 1000 litres.
 
The active inhibitor reserve can be measured using a simple nitrite closed system testkit.

Industries and related products

Description :::

Nitrite based Corrosion Inhibitor for Water and Glycol Brine system is a multimetal corrosion inhibitor based on nitrate and other organic compounds with special yellow metal corrosion inhibitor and antiscaling chemical that helps to prevent scale deposition or also removes adhering loose scale deposits from the heat transfer fluid system.

The disadvantages of not treating the closed circuit water can be equally troubling for the system operator:-
1. Leakage in PHE and AHU due to corrosion
2. Plugging and clogging of tubes and reduced flow rate
3. REduced heat transfer
4. Need of regular descaling that incurs shutdowns, loss of labour and time
5. Fouling of brine of chilled water

Chemical treatment removes dissolved oxygen that causes oxidation of metal to metal oxide i.e., Iron + Oxygen = Iron Oxide (Rust)

The chemical also contains a specific inhibitor to protect the copper from corrosion and removes/prevents any sort of scale formation in the system.

Application :::

Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant, Process chilling and heating system etc.

DOSAGE :::

Nitrite base Corrosion Inhibitor for Water and Glycol Brine is normally fed continuously to the re-circulating closed system by injection dosing pump of dosed to the expansion tank. The amount of Nitrite base Corrosion Inhibitor for Water and Glycol Brine required inhibiting corrosion depends on the type of system and plant operating conditions. The specific dosage rates can be specified by the testing and given parameter.

Specification :::

Chemical Type  Organic Chemical Compound
Form Liquid
Specific Gravity 1.1+_0.05
pH 12+_1  
Soluble in Water Solubility Completey

Benefit :::

Zero or negligible loss of metal or corrosion Excellent heat transferability and flow rate No need of descaling closed circuit equipment Long and extended life of Water without fouling.


TREATMENT                         Feature
Sodium Nitrate                       Iron and Steel corrosion inhibitor. 800-2500 ppm recommended.
Molybdate                              Slows the growth of bacteria.
Tolyltriazole                            Copper corrosion Inhibitor.
Synthetic polymer                  Prevents hard scale built up.
Borax buffer                           Corrects the water pH (Maintain pH level between 8.5 to 9.2).
Silicates                                 A common corrosion inhibitor used by automotive antifreeze suppliers is silicates. Silicates have the disadvantage of building up an insulating layer on components and are not recommended for industrial engines. Concentration should not exceed 25 ppm.

Dosage

TYPICAL DOSE : 5 – 7 litres / 1000 litres of system water and make-up

Nitrite base Corrosion Inhibitor for Water and Glycol Brine is normally fed continuously to the re-circulating closed system by injection dosing pump of dosed to the expansion tank. The amount of Nitrite base Corrosion Inhibitor for Water and Glycol Brine required to inhibit corrosion depends on the type of system and plant operating conditions. The specific dosage rates can be specified by the testing and given parameter.

Also known as

Corroban 40 Nitrite Corrosion Inhibitor

Notes

Benefit :::

Zero or negligible loss of metal or corrosion Excellent heat transferability and flow rate No need of descaling closed circuit equipments Long and extended life of Water without fouling.

 

RXSOL-40-4023  is a high performance nitrite based closed circuit inhibitor.

RXSOL-40-4023  is a high performance nitrite based closed circuit inhibitor.

Nitrite based Corrosion Inhibitor for Water and Glycol Brine system is a multimetal corrosion inhibitor based on nitrate and othe organic compounds with special yellow metal corrosion inhibitor and antiscaling chemical that helps to prevent scale deposition or also removes adhering loose scale deposits from the heat transfer fluid system.

The disadvantages of not treating the closed circuit water can be equally troubling for the system operator:-
1. Leakage in PHE and AHU due to corrosion
2. Plugging and clogging of tubes and reduced flow rate
3. REduced heat transfer
4. Need of regular descalling that incurs shutdowns, loss of labor and time
5. Fouling of brine of chiller water

Chemical tratment removes dissolved oxygen that cause oxidation of metal to metal oxide i.e., Iron + Oxygen = Iron Oxide (Rust)

The chemical also contains a specific inhibitor to protect copper from corrosion and removes/prevents any sort of scale formation in the system.

Remarks

TREATMENT                         Feature
Sodium Nitrate                       Iron and Steel corrosion inhibitor. 800-2500 ppm recommended.
Molybdate                              Slows the growth of bacteria.
Tolyltriazole                            Copper corrosion Inhibitor.
Synthetic polymer                  Prevents hard scale built up.
Borax buffer                           Corrects the water pH (Maintain pH level between 8.5 to 9.2).
Silicates                             A common corrosion inhibitor used by automotive antifreeze suppliers is silicates. Silicates have the disadvantage of building up an insulating layer on components and are not recommended for industrial engines. Concentration should not exceed 25 ppm.
 
Traditional nitrite based inhibitor
Cost effective
Excellent protection
Protects steel, cast iron, copper & brass
Not recommended for aluminium
Suitable for chilled water, LTHW systems

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.

Questions about CorroSOL 40 Nitrite Corrosion Inhibitor

Who is the largest CorroSOL 40 Nitrite Corrosion Inhibitor supplier in Oman?

Oman Chem (Muscat & Barka for Business Trading) is the largest CorroSOL 40 supplier in Oman. We manufacture this RXSOL inhibitor ourselves and keep it in stock at our Barka warehouse.

Can CorroSOL 40 be used in a glycol brine system?

Yes. It treats glycol brine and process chilling circuits as well as plain water chilled and heating loops.

Does CorroSOL 40 stop scale as well as corrosion?

Yes. It contains an antiscaling agent that helps prevent scale deposits and lifts loose scale from heat transfer surfaces. This cuts the need for descaling shutdowns.

How often should I test the nitrite level?

Test regularly on a sample of circulating water, and always after a drain down or large top up. A steady reading means the loop is protected, while a falling one needs a top up and a check for leaks or bacteria.

Can CorroSOL 40 be used in an open cooling tower?

No. It is made for closed recirculating circuits. Open towers lose water all the time and need a different treatment programme.

What is the price of CorroSOL 40 Nitrite Corrosion Inhibitor in Oman?

We quote each order by pack, quantity and delivery point. Send your requirement on WhatsApp or through the quote form for today's price.