Product code RXSOL-43-4029-025Category Cooling Water Chemical

Price and availability on request. Send us the quantity and delivery location in Oman.

EcoGuard Corrosion Protection PolyPhos supplier and manufacturer in Oman

In short: EcoGuard Corrosion Protection PolyPhos is our liquid phosphate and polyphosphate corrosion and scale inhibitor for open recirculating cooling water. We manufacture this RXSOL formulation and are the largest EcoGuard Corrosion Protection PolyPhos supplier in Oman. We keep it in stock at our Barka warehouse in 25 L cans, 210 L drums and 1000 L IBCs. It suits cooling tower and cooling circuit treatment where corrosion and deposits need to be controlled. We deliver to Muscat, Sohar, Salalah and Duqm. Send us your quantity on WhatsApp for today's price.

When does a cooling tower need corrosion and scale treatment?

Open cooling systems need an ongoing treatment programme because water quality and operating conditions change. Look for these signs when reviewing your system:

  • Rust-coloured water or deposits appear in the basin or circuit.
  • Leaks develop, or corrosion coupons show increased metal loss.
  • Scale builds up on cooling surfaces and heat-transfer performance declines.
  • Silt or deposits keep returning to the basin or cooling circuit.

EcoGuard helps protect mild steel, copper, brass and other yellow metals. Its polyphosphates form a protective film and help control scale. Polymers and a dispersant help keep scale, corrosion products and silt from building up. The formulation also uses zinc synergy and an addition for copper and brass protection.

EcoGuard cooling water inhibitor dose for your system

System or conditionProduct dose and treatment
Open recirculating cooling towerTypically 50 to 150 ppm in recirculating water, fed continuously
Open tower with high-corrosion conditionsUp to 200 ppm, depending on metallurgy and water quality
Boiler or RO unit or membraneThe CRM lists these applications, but the open-tower dose does not establish the dose for this equipment. We can assess suitability and the treatment programme for your system.

Choose the dose using your water analysis and system metals. The preferred operating pH is 7.0 to 8.5. Monitor system water for residual phosphate at 2 to 5 ppm and zinc at 0.5 to 1.5 ppm. Adjust the programme against the readings and corrosion results.

Step by step: dosing EcoGuard in an open cooling tower

  1. Check the makeup and recirculating water analysis, system metals and current treatment programme.
  2. Select a starting dose within the stated range for the water and operating conditions.
  3. Set a dosing pump to inject EcoGuard continuously into the cooling water basin or line.
  4. Test the recirculating water for pH, phosphate and zinc residuals.
  5. Adjust the feed to maintain the stated residuals, and record the readings alongside corrosion and deposit observations.
  6. Keep blowdown, dispersant and biological control working as part of the complete water treatment programme.

EcoGuard is fully water-soluble. No product-specific dilution ratio is supplied, so contact us for feed-tank and dilution instructions before preparing a solution.

Using EcoGuard with cooling water biocides

EcoGuard is listed as compatible with sodium hypochlorite, non-oxidising biocide and antiscalant treatments. The inhibitor does not replace biological control. A cooling water biocide such as MICRO BIOCIDE Cooling Water can form part of the programme. Arrange the feed points and check compatibility for your site's chemicals and operating conditions.

Mistakes to avoid with phosphate cooling water treatment

  • Choosing the dose by tower size alone. Water quality, system metals and measured residuals determine the treatment needed.
  • Feeding without testing. Too little or too much product can leave the programme out of control. Record residuals and adjust the pump.
  • Ignoring blowdown and deposits. Manage blowdown and dispersant control to help prevent calcium phosphate deposits.
  • Using the tower dose for a boiler or RO membrane. These systems need an equipment-specific suitability and dosing assessment.
  • Leaving out biological control. Corrosion and scale inhibition is one part of cooling water treatment.

Safety, storage and MSDS

Use the protective equipment specified for the product. For hazards, storage, spills and disposal, read the MSDS: press "Get MSDS" at the top of this page to request it. Check local discharge requirements for treated cooling tower blowdown, including any applicable phosphate and zinc limits.

EcoGuard Corrosion Protection PolyPhos or another product?

  • Open recirculating cooling water needing corrosion and scale control: EcoGuard.
  • Biological control alongside the inhibitor: consider BIOCIDE as part of the treatment programme.
  • Additional dispersant for cooling water deposits: consider HydroDisperse Polymer Dispersant where the water analysis and deposit problem call for it.

EcoGuard Corrosion Protection PolyPhos price and quotation in Oman

We keep EcoGuard in stock at Barka in 25 L cans, 210 L drums and 1000 L IBCs. The price depends on the pack, quantity and delivery point. To buy, send your quantity, pack and location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers get volume prices. We deliver from Barka to Muscat, Sohar, Salalah and Duqm.

Overview

Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.

Product description

Corrosion Scale Inhibitor Phosphate Based is a multi-metal corrosion inhibitor designed for use in open loop cooling water systems. It provides effective protection for mild steel, copper, and yellow metals, while minimizing scale and deposit formation. The formulation combines proprietory polymers specially manufactured for superior film-forming and corrosion control under various water qualities.

Applications

Corrosion Inhibitor OPEN Cooling System  scientifically formulated to keep clean open recirculating systems  and also prevent from scale formation . Chemically Corrosion Inhibitor OPEN Cooling System  will disperse scale and corrosive products, silt etc and can be used as an anti-foulant along with other treatments. 

Excellent scale inhibition for a variety of applications including cooling circuits, boilers and RO units.

It is widely used in Boilers, cooling water and membranes

Dosage

Dosage

 
System Type Typical Dosage
Open Loop Cooling Towers 50 – 150 ppm in recirculating water
High-corrosion conditions Up to 200 ppm based on metallurgy and water quality
pH Control Range Operates best between pH 7.0 – 8.5
  • Dosing Method: Continuous injection via dosing pump into cooling water basin or line.
  • Monitoring: Maintain residual phosphate at 2–5 ppm and zinc at 0.5–1.5 ppm in system water

  • Compatible with: Sodium hypochlorite, non-oxidizing biocide: RXSOL-40-4009-025, anti-scalants: RXSOL-33-3302-025.

Also known as

TRASAR 3DT 250, Corrosion Inhibitor with Zinc salts and Polyphosphates, Corrosion and Scale Inhibitor Phosphate Based, Acumer 3100, Coolguard 613

Notes

Features & Benefits


Feature Benefit
Multi-metal protection Effective for steel, copper, and brass
Polyphosphate base Film-forming corrosion inhibition + sequestering
Zinc synergy Boosts performance, even in aggressive waters
Proprietory addition Superior copper/brass protection
Dispersant included Minimizes fouling from calcium or debris
Easy to dose Liquid product, fully water-soluble
Environmentally safer Alternative to chromate-based inhibitors

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.

Questions about EcoGuard Corrosion Protection PolyPhos

Who is the largest EcoGuard Corrosion Protection PolyPhos supplier in Oman?

Oman Chem is the largest EcoGuard Corrosion Protection PolyPhos supplier in Oman. We manufacture the RXSOL formulation and keep it in stock at our Barka warehouse.

What does EcoGuard PolyPhos do in a cooling tower?

It helps control corrosion and scale in open recirculating cooling water. Its dispersant also helps limit deposits from scale, corrosion products and silt.

Which metals does EcoGuard protect?

It is designed for systems containing mild steel, copper, brass and other yellow metals. Water quality and the complete treatment programme affect performance.

How much EcoGuard should I dose in an open cooling tower?

The typical dose is 50 to 150 ppm in recirculating water, with up to 200 ppm under high-corrosion conditions. Feed it continuously and monitor pH and phosphate and zinc residuals.

Can EcoGuard be used with sodium hypochlorite?

Yes, it is listed as compatible with sodium hypochlorite. Check the site's complete chemical programme and feed arrangements.

What is the price of EcoGuard Corrosion Protection PolyPhos in Oman?

We quote each order by pack, quantity and delivery point. Send your requirement on WhatsApp or through the quote form for today's price.