Product code RXSOL-40-4026-025Category Cooling Water Chemical

Price and availability on request. Send us the quantity and delivery location in Oman.

Corrosion Inhibitor Antifoulant for Aluminium cooling system supplier and manufacturer in Oman

In short: Corrosion Inhibitor Antifoulant for Aluminium cooling system is our own RXSOL treatment for closed circulating water. We manufacture and supply it for aluminium and mixed-metal chilled water and low-pressure heating systems. We are the largest Corrosion Inhibitor Antifoulant for Aluminium cooling system supplier in Oman and keep it in stock at our Barka warehouse. We supply 25 L cans, 210 L drums and 1000 L IBCs for delivery to Muscat, Sohar, Salalah and Duqm. Send us your quantity on WhatsApp for today's price.

When does a closed aluminium cooling system need treatment?

A new or refilled closed loop needs corrosion protection before damage becomes visible. RXSOL combines organic and inorganic inhibitors, including molybdate, to protect aluminium, steel, copper and other nonferrous metals.

Test the circulating water if the inhibitor reserve falls, or if the system needs repeated makeup water. Leaks and makeup water can introduce oxygen and affect corrosion control. Pitting, corrosion deposits, fouled heat exchangers or reduced cooling performance also warrant investigation. These signs can have several causes, so test the water and inspect the circuit before deciding on corrective work.

RXSOL dose for closed chilled water and heating systems

SystemProduct doseSodium molybdate reserve
Closed circuit containing aluminium1 to 1.5%Minimum 100 ppm
Closed circuit without aluminium0.5 to 1%, or 5,000 to 10,000 mL per cubic metre50 ppm

For an aluminium-containing circuit, 1 to 1.5% is 10 to 15 litres per cubic metre of system water. Where aluminium is present, keep the circulating-water pH between 7 and 8. A separate pH conditioner may be needed.

Systems needing significant passivation may require a higher initial dose to reach the required reserve. Base any increase on the water test and technical advice.

Step by step: dosing an aluminium closed cooling system

  1. Establish the system water volume and identify the metals in the circuit.
  2. Review the water quality and compatibility with any treatment or glycol already in the system.
  3. Measure the product for the system volume using the aluminium dose in the table.
  4. Add it to the closed circulating water and circulate it through the system.
  5. Test the water for sodium molybdate and pH. Use a test that reports the reserve as sodium molybdate.
  6. Adjust the treatment or pH as needed, then record the results. Test again during operation, especially after water loss or makeup.

If the circuit contains deposits or corrosion products, investigate whether it needs cleaning before treatment. Inhibitor protects the circulating system, but it does not remove established deposits.

Mistakes to avoid with aluminium cooling water treatment

  • Using it with a Stelrad Super Plus Modular boiler. This product must not be used in systems containing that boiler. Use an alternative treatment.
  • Using the lower, non-aluminium dose in an aluminium circuit. Aluminium systems need the dose and minimum reserve shown in the table.
  • Leaving the pH outside the specified range. Aluminium protection depends on controlling the circulating-water pH.
  • Assuming existing chemicals are compatible. Check the actual glycol, brine, inhibitors, biocides, seals and equipment before mixing treatments.
  • Using an initial dose as the only control. Measure the reserve after dosing and during operation. Find and repair leaks that cause repeated water loss.
  • Treating an open cooling tower with this closed-loop programme. Open systems need a treatment selected for their operating conditions.

Safety, storage and MSDS

Avoid skin and eye contact, prevent spills, and keep the product in its original, labelled container with the lid closed. Read the product-specific MSDS for hazards, protective equipment, first aid, spill response, storage and disposal: press "Get MSDS" at the top of this page to request it.

Corrosion Inhibitor Antifoulant for Aluminium cooling system or another product?

  • Aluminium in a closed chilled water or low-pressure heating circuit: use this RXSOL treatment and control the molybdate reserve and pH as shown above.
  • A separate microbial treatment is needed: consider BIOCIDE for Closed Loop Chilled Water as part of a compatible treatment programme. The antifoulant description does not make the inhibitor a substitute for a specified biocide.
  • A closed chilled water system needs a different inhibitor: consider Corrosion Inhibitor Multifunctional Closed Chilled Systems. Select the treatment for the circuit metals and water chemistry.
  • Antifreeze protection is required: consider an inhibited heat-transfer fluid such as Anti Freeze RXSOL PROCOOL 50/50, subject to equipment and chemical compatibility. The aluminium inhibitor alone is not an antifreeze.

If you currently use Accepta 2309 or Hydrex 2610, compare the product and equipment specifications before changing treatments. The required residual and compatibility depend on the formulation.

Corrosion Inhibitor Antifoulant for Aluminium cooling system price and quotation in Oman

We stock 25 L cans, 210 L drums and 1000 L IBCs at Barka. Price depends on the pack, quantity and delivery point, so we quote every order. Send your quantity, pack and location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers get volume prices. Buy from us for delivery from Barka to Muscat, Sohar, Salalah and Duqm.

Overview

Superior corrosion inhibitor developed for use in closed water circulating systems containing aluminium

Product description

Corrosion inhibitor/antifoulant - aluminium cooling & closed circuit systems

RXSOL-40-4026-025 is a superior corrosion inhibitor developed for use in closed water circulating systems containing aluminium. RXSOL-40-4026-025 is based on a novel blend of organic and inorganic corrosion inhibitors, including molybdate, intended to protect steel, copper and other nonferrous metals. RXSOL-40-4026 is an ideal treatment for closed chilled water and low pressure heating systems. Whilst RXSOL-40-4026 is designed to protect systems which incorporate aluminium, it should NOT be used in systems with “Stelrad Super Plus Modular” boilers where an alternative product should be used. In all applications of  RXSOL-40-4026, where aluminium is present it is important to control the pH in the range 7-8.

Dosage

Dosing of RXSOL-40-4026 - For systems containing no aluminium RXSOL-40-4026 should be dosed at 0.5 to 1% (5,000 - 10,000 ml/m3 ) in order to give a reserve of 50ppm of sodium molybdate.
For systems containing aluminium the dosage of 1-1.5% should be added in order to maintain a minimum reserve of 100ppm of sodium molybdate.
In certain circumstances it may be necessary to adjust the pH separately by the addition of pH conditioner. In systems requiring significant passivation higher initial dosages may be required to yield the required inhibitor residual.

Also known as

Accepta 2309, Hydrex 2610

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.

Questions about Corrosion Inhibitor Antifoulant for Aluminium cooling system

Who is the largest Corrosion Inhibitor Antifoulant for Aluminium cooling system supplier in Oman?

Oman Chem is the largest supplier in Oman. We manufacture this RXSOL formulation and stock it at our Barka warehouse.

Can I use RXSOL in a closed chilled water loop containing aluminium and copper?

Yes. The treatment is intended for closed circulating systems containing aluminium and protects copper, steel and other nonferrous metals.

How much inhibitor does an aluminium cooling system need?

Dose at 1 to 1.5% of the system water volume and maintain at least 100 ppm sodium molybdate. That is 10 to 15 litres of product per cubic metre of system water.

How do I test the inhibitor reserve?

Use a suitable molybdate test and make sure the result is reported as sodium molybdate. Record the result alongside the circulating-water pH.

Can this corrosion inhibitor be used with glycol?

Compatibility depends on the glycol formulation and the existing treatment. Check both before adding the inhibitor to the circuit.

What is the price of Corrosion Inhibitor Antifoulant for Aluminium cooling system in Oman?

We quote each order according to the pack, quantity and delivery point. Send your requirement on WhatsApp or through the quote form.