Product code RXSOL-40-4031-025Category Cooling Water Chemical

Price and availability on request. Send us the quantity and delivery location in Oman.

RXSOL BIOCIDE MAR supplier and manufacturer in Oman

In short: RXSOL BIOCIDE MAR is our liquid microbiocide for controlling microbial growth in cooling water. We manufacture this RXSOL formulation and supply it for marine and industrial cooling systems. We are the largest RXSOL BIOCIDE MAR supplier in Oman and keep it in stock at our Barka warehouse. We deliver to Muscat, Sohar, Salalah and Duqm in 25 L cans, 210 L drums and 1000 L IBCs. Send us your quantity on WhatsApp for today's price.

When does cooling water need a biocide?

Bacteria and other microbes can grow in open and closed cooling water systems. Deposits can reduce heat transfer and contribute to corrosion. In a closed circuit, microbial contamination can also cause acid formation and use up nitrite corrosion inhibitor.

Look for these signs when investigating a cooling system:

  • Dip-slide tests show bacterial contamination or a rising microbial count.
  • Slime, biofilm or deposits collect in the system.
  • Heat-transfer performance falls or corrosion appears under deposits.
  • Nitrite inhibitor levels fall or the water becomes acidic.

Warm conditions and long periods alongside increase the need for monitoring, but do not by themselves prove contamination. Clear water does not prove that bacteria are under control. Use regular dip-slide tests and record the results. Ordinary aerobic dip slides do not test for Legionella, which needs a separate risk-based testing and control programme where applicable.

RXSOL BIOCIDE MAR doses for cooling water and marine oil systems

Choose the dose for the job and calculate it from the system contents. The general cooling-water dose is different from the treatment for a contaminated closed circuit.

Your situationRXSOL BIOCIDE MAR doseTreatment
General cooling-water treatment0.5 to 1 litre per ton of waterUse as part of the cooling-water treatment programme for the system.
Contaminated closed cooling circuit1.5 to 2.5 litres per ton of waterCirculate for 3 days, then discharge and flush as described below.
Contaminated lubricating-oil sump1 to 1.5 litres per ton of oil remaining in the sumpCirculate for 12 to 24 hours during the oil-system cleaning procedure.
Lubricating oil awaiting full disinfection0.5 to 1 litre per ton of oilAdd directly to slow microbial growth until the full treatment is carried out.

For oil systems, confirm the dose with the oil manufacturer. Water entering oil can encourage microbial growth, emulsification and blocked filters. Remove the source of water ingress as part of the corrective work.

Step by step: disinfecting a marine closed cooling circuit

  1. Test the cooling water for bacteria and calculate the circuit volume. Clean or degrease first if heavy scale or oil fouling is present.
  2. Keep evaporators and other equipment connected to drinking-water production out of use during disinfection.
  3. Add 1.5 to 2.5 litres of RXSOL BIOCIDE MAR per ton of water and circulate for 3 days.
  4. Discharge the entire contents and flush the circuit thoroughly with fresh water. Arrange disposal of treated water and residues according to local requirements.
  5. Refill with distilled water and add the appropriate corrosion inhibitor at its recommended dose. Options include RXSOL 2000 Corrosion Inhibitor and Cool Water Treat Corrosion Inhibitor.
  6. After 24 hours of operation, test again for bacteria. Repeat the disinfection procedure if contamination persists.

Using RXSOL BIOCIDE MAR in lubricating oil

For a contaminated oil system, transfer 80 to 90% of the oil to a renovation tank. Heat it to 85 to 95 °C and separate it for 12 hours, then continue heating for another 12 hours without separation. Treat the oil remaining in the sump at the dose in the table and circulate it. Dead microbes can block filters, so clean them as needed.

Empty and clean the sump before returning the treated oil and topping up with fresh oil. If contamination has already caused corrosion, replace the oil and consult its manufacturer. Before refilling, flush for 24 hours with flushing oil containing 0.5 to 1 litre of biocide per ton. Add 0.1 to 0.5 litres per ton to new oil to help prevent reinfection.

Mistakes to avoid

  • Using the general dose for a contaminated closed circuit. A contaminated circuit needs the higher dose, circulation, discharge and flush described above.
  • Leaving heavy deposits in place. Remove scale and oil fouling before disinfection so the treatment can reach the system surfaces.
  • Calculating from the tank alone. Use the contents of the circuit when working out the dose.
  • Relying on biocide as a corrosion inhibitor. Refill the cleaned circuit with the correct inhibitor and maintain its treatment level.
  • Overlooking blocked oil filters. Monitor and clean filters during oil-system treatment as dead microbes collect in them.

Safety, storage and MSDS

Avoid any contact with drinking water. Store securely and out of reach of children and pets. Read the current product-specific MSDS and label for protective equipment, ventilation, storage, spills and disposal. Press "Get MSDS" at the top of this page to request it.

RXSOL BIOCIDE MAR or another product?

  • Microbial growth in open or closed cooling water: RXSOL BIOCIDE MAR. It also has a specified procedure for contaminated lubricating-oil systems.
  • Another cooling-water biocide: MICRO BIOCIDE Cooling Water. Select the treatment for the system and organisms involved.
  • Biofilm and fouling control alongside a biocide: Bio Dispersant Cooling Water Treatment Fouling Control. A dispersant does not automatically replace a biocide.

RXSOL BIOCIDE MAR price and quotation in Oman

We keep RXSOL BIOCIDE MAR in stock at Barka in 25 L cans, 210 L drums and 1000 L IBCs. The price depends on the pack, quantity and delivery point. To buy, send your quantity, pack and location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers get volume prices. We deliver from Barka to Muscat, Sohar, Salalah and Duqm, including ships at Port Sultan Qaboos, Sohar Port, Salalah Port and Duqm.

Overview

Cooling Water Biocide to control microbiological growth

Product description

Micororganism control in a cooling system is big task. RXSOL BIOCIDE not only control growth of organism in a cooling water, but also hleps to maintain clear water in a cooling system.

RXSOL BIOCIDE MAR is a powerful microbiocide which will control a wide range of troublesome microbes in both open and closed water systems.

Applications

Growth of bacteria not only resulting corrosion on metal surface but also reduces heat transfer capacity.

Dosage

Its low label presence like half to one ltr behind per ton of water effectively control bacterial growth in cooling system.

Also known as

Micororganism Control, Biocide for Cooling System, Biological Organism control in Cooling Water, MAXTREAT 2730, MAXTREAT 608, MAXTREAT 617 G, ROCOR BC 601, MAR-71

Notes

Directions for Use
 
Closed Cooling Water Circuits
  • When vessels remain berthed for extended periods in warm climates, cooling water systems are at high risk of microbial contamination. Such contamination leads to acid formation and depletion of nitrite-based corrosion inhibitors, resulting in under-deposit corrosion.
  • Regular bacterial testing using dip slides is strongly recommended.
  • If contamination is detected, dose 1.5-2.5 litres/ton of MAR BIOCIDE RXSOL into the system.
  • Circulate the system for three days, then discharge the entire contents.
  • Flush thoroughly with fresh water before refilling with distilled water and adding a corrosion inhibitor.
  • Suitable inhibitors include nitrite-based products (Roccor NB Corrosion Inhibitor, RXSOL 2000) or organic-based products (Cool Water Treat Corrosion Inhibitor), applied as per their respective guidelines.
  • Retest for bacteria after 24 hours of operation and repeat the procedure if contamination persists.
  • For heavily fouled systems (scale/oil), perform acid cleaning and/or degreasing before disinfecting.
 
Caution: During disinfection, do not use evaporators or other equipment connected to potable water production.
 
Lubricating Oils
  • Water ingress into lubricating oils (from condensation or cooling water leaks) creates ideal conditions for microbial growth. This can alter oil properties, cause corrosion, emulsification, and filter blockages.
  • Regular monitoring and corrective treatment can prevent such problems.
  • Recommended decontamination procedure:
  • Transfer 80–90% of the lubricating oil to a renovation tank. Heat to 85–95 °C and separate for 12 hours. Continue heating another 12 hours without separation.
  • Add 1-1.5 litre/ton MAR BIOCIDE RXSOL to the oil remaining in the sump tank. Circulate for 12–24 hours. Expect filters to clog with dead microbes; clean as necessary.
  • Empty and clean the sump tank.
  • Return the treated oil from the renovation tank to the sump and top up with fresh oil.
  • Alternatively, microbial growth can be slowed by adding 0.5–1.0 litres/ton MAR BIOCIDE RXSOL directly to the lubricating oil, though full disinfection must follow later.
  • Always confirm dosage with the oil manufacturer. If microbial contamination has already caused corrosion, replace the oil entirely and consult the manufacturer.
  • Before refilling, flush the system for 24 hours with flushing oil containing 0.5–1 litre/ton MAR BIOCIDE RXSOL.
  • To prevent reinfection, add 0.1–0.5 litres/ton MAR BIOCIDE RXSOL to the new oil.

Remarks

Avoid any contact with DRINKING water.

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.

Questions about RXSOL BIOCIDE MAR

Who is the largest RXSOL BIOCIDE MAR supplier in Oman?

Oman Chem is the largest RXSOL BIOCIDE MAR supplier in Oman. We manufacture our own RXSOL formulation and keep it in stock at our Barka warehouse.

What is RXSOL BIOCIDE MAR used for?

It controls troublesome microbes in open and closed cooling-water systems, including marine circuits. It can also be used in lubricating-oil systems under the specified treatment procedure.

How much RXSOL BIOCIDE MAR should I add to cooling water?

The general dose is 0.5 to 1 litre per ton of water. A contaminated closed circuit needs 1.5 to 2.5 litres per ton and the full disinfection procedure.

Can RXSOL BIOCIDE MAR be used in lubricating oil?

Yes. It can be used to treat microbial contamination in an oil system, with the dose confirmed by the oil manufacturer.

Can I use a dip slide to test for Legionella in cooling water?

Ordinary aerobic dip slides do not test for Legionella. Use a separate risk-based Legionella testing and control programme where applicable.

What is the price of RXSOL BIOCIDE MAR in Oman?

We quote each order by pack, quantity and delivery point. Send your requirement on WhatsApp or through the quote form for today's price.