Product code RXSOL-33-3345-260Category RO Chemicals

Price and availability on request. Send us the quantity and delivery location in Oman.

Overview

RO CLEANER 4030 is a low pH liquid cleaner designed to remove metal foulants such as iron, manganese, and aluminium as well as calcium carbonate scale deposits from spiral wound polyamide and cellulose acetate elements.

Product description

RO CLEANER 4030 is a low pH liquid cleaner designed to remove metal foulants such as iron, manganese, and aluminium as well as calcium carbonate scale deposits from spiral wound polyamide and cellulose acetate elements. RO CLEANER 4030 is made according to  ANSI/NSF Standard 60 for use as an off-line cleaner in drinking water systems.

Applications

Scale deposits remover from spiral wound polyamide and cellulose acetate elements.

Dosage

Use Instructions:

1. Fill the cleaning tank to the desired volume with RO permeate or DI water. Heat the solution to the maximum acceptable temperature (see membrane manufacturer guidelines) as this will dramatically increase the cleaning efficiency. Add sufficient RO CLEANER 4030  to create a 2% wt/wt solution if the fouling is moderate/severe or 1% if the fouling is mild. Recycle the solution through the cleaning tank to ensure adequate mixing.

2. Recirculate the cleaning solution through each RO system stage, one at a time, for a minimum of 60 minutes at the flow rate recommended by the membrane
manufacturer. If that rate is not known, use the guidelines listed below:

 

Element Diameter, inches

Flow Rate per Vessel, gpm (m3/hr)

4

10 (2.4)

8

40 (9.0)

3. If the membranes are heavily fouled and the recirculated cleaning solution becomes discolored or turbid, discard as much as 15% of the solution volume. Heavily fouled elements may also benefit from a soak period (up to 8 hours).

4. Monitor the pH of the solution during the cleaning process. If the pH remains in the desired range and the solution is not turbid, it may be used to clean subsequent stages. In the unlikely event the pH rises, prepare a new batch and repeat steps 1-4.

5. When the clean is completed, rinse the membranes by recirculating RO permeate through each pressure vessel. To comply with NSF standards, the cleaner should be flushed out with 5 bed/volumes of water before putting the system back on-line.

Also known as

RoClean L403

Notes

PERFORMANCE :

RO CLEANER 4030 offers an array of performance benefits:

  • Compatible with all polyamide and cellulose acetate membranes.
  • Contains a special blend of buffers, chelants, and reducing agents, to promote the dissolution of metal deposits.
  • Superior results to generic citric and hydrochloric acid solutions.
  • Highly buffered to resist pH changes during the cleaning process.
  • Can be used in conjunction with other applicable cleaners to remove combination foulants.
  • Temperature compensated to maintain optimum pH over a wide temperature range.

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah) and in India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), and we also supply to South Africa.