Price and availability on request. Send us the quantity and delivery location in Oman.
Corrosion Inhibitor CI 3023 supplier and manufacturer in Oman
In short: Corrosion Inhibitor CI 3023 is our own RXSOL film-forming corrosion inhibitor for oil and gas production and pipeline systems. We manufacture it and keep it in stock at our Barka warehouse, and we are the largest Corrosion Inhibitor CI 3023 supplier in Oman. It is injected into crude oil pipelines, flowlines, gathering lines and production equipment to cut internal corrosion of carbon steel. We supply it in 210 L drums and in bulk, and deliver to Muscat, Sohar, Salalah and Duqm. Send us your quantity on WhatsApp for today's price.
How CI 3023 protects pipelines and production lines
CI 3023 works by forming a film on the metal. Its active components adsorb onto the steel surface and build a barrier between the metal and the corrosive fluid. That barrier slows the electrochemical reactions that eat into the pipe wall.
Under flowing conditions the film wears away over time. Continuous injection replenishes it and keeps the protection in place along the line. Our catalogue lists CI 3023 as an alternative to KI 3939, so operators switching from that product can trial it on their own fluids.
When a pipeline needs a corrosion inhibitor
- Corrosion coupons, electrical resistance probes or inspections show rising metal loss.
- Produced water or other corrosive constituents reach susceptible carbon steel surfaces.
- Water cut, fluid composition, temperature or flow rate has changed, and the old programme no longer fits.
Water in the line is usually where corrosion starts. Dissolved gases and salts in that water make it worse, so the fluid analysis comes first.
Corrosion Inhibitor CI 3023 dosage for oilfield pipelines in Oman
| Application | Where it is used | Dosage |
|---|---|---|
| Continuous pipeline injection | Crude oil pipelines, flowlines, gathering lines | 6 to 12 ppm, preliminary range |
| High-corrosion systems | Severe production fluids | Set by laboratory and field trials |
| Initial film establishment | New or newly treated lines | Site-specific treatment programme |
| Batch treatment | Depends on the line | Subject to system design and validation |
A worked example: a pipeline carrying 100 m³ per hour, treated at 10 ppm by mass, needs about 1 kg of inhibitor per hour. That assumes a fluid density of 1,000 kg/m³. For other densities the inhibitor mass flow changes, and the injection volume also depends on the inhibitor's own density.
Step by step: starting a continuous injection programme
- Analyse the production fluid: water cut, salinity, dissolved gases and other corrosive constituents.
- Confirm the pipeline metallurgy and the operating temperature.
- Select a suitable chemical injection point.
- Set the preliminary dose through laboratory testing, starting from the 6 to 12 ppm range.
- Inject continuously with a calibrated chemical dosing pump.
- Monitor with corrosion coupons, electrical resistance probes or other approved techniques.
- Adjust the injection rate to the measured corrosion performance.
Useful lab tests include coupon weight-loss, electrochemical testing, emulsion tendency, thermal stability and film persistency. Dynamic flow-loop testing helps where flow conditions are severe.
Mistakes to avoid
- Treating the catalogue cross-reference as a match. CI 3023 is listed as a KI 3939 alternative, not an identical formulation. Compare the documents and trial it on your fluids.
- Using 6 to 12 ppm as a fixed dose. It is a starting range. Your fluids and conditions set the final rate.
- Assuming sour or sweet service. Use in fluids with CO₂ or H₂S only after representative corrosion testing.
- Using it in acidizing fluids. CI 3023 is a pipeline inhibitor. Concentrated acid jobs need an acid corrosion inhibitor tested for that duty.
- Skipping the compatibility check. Test it with your crude, produced water, demulsifiers, scale inhibitors and other production chemicals.
- Relying on probes alone. Coupons and probes show local conditions. They do not replace integrity inspection along the whole pipeline.
Safety, storage and MSDS
Wear chemical-resistant gloves, eye protection and protective clothing when handling the drums and filling the dosing tank. Store CI 3023 in tightly closed, properly labelled containers in a cool, dry, well-ventilated place, out of direct sun. Read the MSDS for hazards, transport classification, fire precautions and spill response: press "Get MSDS" at the top of this page to request it.
Corrosion Inhibitor CI 3023 or another product?
- Internal corrosion in crude oil pipelines, flowlines and production lines: CI 3023.
- Corrosion in gas and oil processing units: Corrosion Inhibitor for Oil and Gas Processing.
- H₂S in production fluids: Hydrogen Sulfide Scavenger, run alongside the inhibitor once compatibility is tested.
- Scale building up with the corrosion: Scale Inhibitor Antiscalant.
- Protecting the outside of pipes and steelwork: Corrosion Inhibitor for External.
Corrosion Inhibitor CI 3023 price and quotation in Oman
The price of Corrosion Inhibitor CI 3023 depends on the pack, the quantity and the delivery point, so we quote every order. We hold stock at Barka in 210 L drums and supply bulk quantities. Send us the quantity, the pack and the delivery location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers and oilfield contractors get volume prices. We deliver from Barka to Muscat, Sohar, Salalah and Duqm.
Overview
Film-forming corrosion inhibitors work by adsorbing onto metal surfaces and forming a protective barrier that reduces contact between corrosive fluids and the underlying metal.
Product description
RXSOL Corrosion Inhibitor CI 3023 is a film-forming corrosion inhibitor
The product is intended to reduce internal corrosion of compatible metallic surfaces in oil and gas production and pipeline transportation systems.
Film-forming corrosion inhibitors work by adsorbing onto metal surfaces and forming a protective barrier that reduces contact between corrosive fluids and the underlying metal.
RXSOL Corrosion Inhibitor CI 3023, code RXSOL-81-8165-211.
THINK CHEMICAL THINK RXMARINE
Applications
RXSOL TECHNICAL PRODUCT BULLETIN
CORROSION INHIBITOR KI 3939
Film-Forming Corrosion Inhibitor for Oil & Gas Production and Pipeline Protection
RXSOL Equivalent Product: Corrosion Inhibitor CI 3023 RXSOL Product Code: RXSOL-81-8165-211 Product Category: Oilfield Chemicals / Pipeline Corrosion Inhibitors Application: Oil & Gas Production, Hydrocarbon Pipelines and Industrial Corrosion Protection
Major Applications
|
Application |
Purpose |
|---|---|
|
Crude Oil Pipelines |
Internal corrosion protection |
|
Oil & Gas Production Lines |
Control of corrosion in production fluids |
|
Flowlines |
Protection of compatible carbon steel surfaces |
|
Gathering Pipelines |
Corrosion management during fluid transportation |
|
Production Equipment |
Reduction of corrosion-related metal deterioration |
|
Industrial Hydrocarbon Systems |
Corrosion control where validated |
Suitability for CO₂-containing or H₂S-containing fluids must be confirmed through representative corrosion testing. Inhibitor performance depends on fluid composition, temperature, flow conditions and metallurgy.
Industries and related products
Frequently Asked Questions
Q1. What is the RXSOL equivalent of Corrosion Inhibitor KI 3939?
RXSOL identifies Corrosion Inhibitor CI 3023 (RXSOL-81-8165-211) as an alternative product. This is a catalogue cross-reference, not proof of identical formulation.
Q2. What is the main application of KI 3939?
The RXSOL-listed alternative is intended for film-forming corrosion protection in oil and gas pipeline systems.
Q3. What is the recommended dosage?
The published range is 6–12 ppm, but actual dosage must be validated under field operating conditions.
Q4. Can it protect against CO₂ and H₂S corrosion?
Potentially, depending on the formulation. Performance under sweet or sour service conditions must be verified through representative testing.
Q5. Is KI 3939 suitable for acidizing?
The available RXSOL cross-reference does not establish suitability for concentrated acidizing fluids. Acid corrosion inhibitors require separate testing for acid strength, temperature, exposure time and metallurgy.
Dosage
Working Mechanism
The intended corrosion inhibition mechanism involves:
Surface Adsorption: Active inhibitor components adsorb onto compatible metal surfaces.
Protective Film Formation: A barrier film reduces exposure of the metal to corrosive components.
Corrosion Rate Reduction: The protective layer helps reduce electrochemical corrosion reactions.
Film Maintenance: Continuous injection may be required to replenish the inhibitor film under flowing conditions.
Recommended Dosage
|
Application |
Preliminary Dosage |
|---|---|
|
Continuous Pipeline Injection |
6–12 ppm, supplier-published range |
|
High-Corrosion Systems |
Determine through laboratory and field trials |
|
Initial Film Establishment |
Site-specific treatment programme |
|
Batch Treatment |
Subject to system design and validation |
Example: For a pipeline carrying 100 m³/hour of fluid, a treatment rate of 10 ppm by mass corresponds to approximately 1 kg/hour of inhibitor if the treated fluid density is assumed to be 1,000 kg/m³.
For other fluid densities, the required inhibitor mass flow changes accordingly.
The actual injection volume also depends on the inhibitor's density.
Also known as
KI 3939 Corrosion Inhibitor 210 Ltr
Notes
Recommended Application Procedure
-
Analyse the production fluid, including water cut, salinity, dissolved gases and other corrosive constituents.
-
Confirm pipeline metallurgy and operating temperature.
-
Select a suitable chemical injection point.
-
Establish the preliminary dosage through laboratory testing.
-
Inject continuously using a calibrated chemical dosing pump.
-
Monitor corrosion performance using coupons, electrical resistance probes or other approved techniques.
-
Adjust the injection rate according to measured corrosion performance.
Remarks
Performance Evaluation
Recommended tests include:
-
Corrosion coupon weight-loss testing.
-
Electrochemical corrosion testing.
-
Compatibility with crude oil and produced water.
-
Emulsion tendency assessment.
-
Thermal stability testing.
-
Film persistency testing.
-
Dynamic flow-loop testing where appropriate.
-
Compatibility with demulsifiers, scale inhibitors and other production chemicals.
Storage & Handling
Store in tightly closed, properly labelled containers in a cool, dry, well-ventilated location.
Use appropriate chemical-resistant gloves, eye protection and protective clothing.
Follow the finished-product SDS for handling, transport classification, fire precautions and spill response.
Packing
Product Code: RXSOL-81-8165-211
Industrial drum and bulk packing availability should be confirmed when requesting a quotation.
Where we supply
Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.
Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.
Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.
Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.
Questions about Corrosion Inhibitor CI 3023
Who is the largest Corrosion Inhibitor CI 3023 supplier in Oman?
Oman Chem (Muscat & Barka for Business Trading) is the largest Corrosion Inhibitor CI 3023 supplier in Oman. We manufacture this RXSOL film-forming inhibitor ourselves and keep it in stock at our Barka warehouse.
Is CI 3023 the same as KI 3939?
No. Our catalogue lists CI 3023 as an alternative to KI 3939, not as an identical formulation. Compare the two data sheets and trial CI 3023 under your own operating conditions.
What dose of CI 3023 is used in a pipeline?
The preliminary range for continuous pipeline injection is 6 to 12 ppm. Laboratory and field monitoring then set the final rate for your line.
Does CI 3023 work in sour or CO2 service?
It can, depending on the fluids. Its suitability for fluids with CO₂ or H₂S has to be shown by representative corrosion testing first.
Can CI 3023 be used for acidizing?
No. It is a film-forming inhibitor for production and pipeline fluids. Concentrated acid jobs need an acid corrosion inhibitor tested for that service.
What is the price of Corrosion Inhibitor CI 3023 in Oman?
We quote each order by pack, quantity and delivery point. Send your requirement on WhatsApp +968 7733 3599 or through the quote form on this page for today's price.

