Product code RXSOL-40-4019-025Category Cooling Water Chemical

Price and availability on request. Send us the quantity and delivery location in Oman.

CorroGuard Cooling Water Antifoulant supplier and manufacturer in Oman

In short: CorroGuard Cooling Water Antifoulant is our RXSOL cooling water treatment for corrosion and microbial fouling control. We manufacture and supply it for industrial cooling systems, especially closed circuits. We are the largest CorroGuard Cooling Water Antifoulant supplier in Oman and keep it in stock at our Barka warehouse. We deliver to Muscat, Sohar, Salalah and Duqm. We will tell you the packs in stock when you order. Send us your quantity on WhatsApp for today's price.

When does cooling water need attention?

Your water tests and operating records can show corrosion or fouling before a heat exchanger loses performance:

  • Iron or copper readings rise, or the circulating water turns cloudy.
  • Slime or deposits appear in the system, or flow through a heat exchanger becomes restricted.
  • Heat transfer declines under comparable operating conditions.
  • The inhibitor residual falls, makeup water demand increases, or microbial growth appears.

These signs call for an investigation of the water and the system. A leak can bring in fresh water and dilute the inhibitor. Deposits and microbial growth can also make it harder to maintain a clean heat transfer surface.

CorroGuard for closed cooling water circuits in Oman

CorroGuard is a low nitrite and molybdate based treatment developed for closed circuits. It also contains acrylic copolymer and isothiazoline microbiocide. The blend addresses corrosion and microbial fouling in industrial cooling water.

Your systemWhat to consider
Closed chilled water or industrial cooling circuitChoose the treatment programme for the system volume, metals, water quality and existing chemicals.
Open recirculating cooling water systemCorroGuard is also listed for corrosion and fouling control in open systems. We will confirm its suitability for your tower and treatment programme before use.
Fouled circuit or heat exchangerInvestigate deposits and microbial growth. Cleaning and flushing may be needed before the treatment programme starts.

The dose and any dilution depend on the system. Send us your water analysis and operating details for a product-specific recommendation.

Step by step: treating a cooling water circuit

  1. Identify the system volume, metals, makeup water quality, operating conditions and chemicals already in use.
  2. Obtain the current technical data sheet and our recommended dose, dilution and monitoring programme for your circuit.
  3. Inspect the system for leaks and fouling. Clean and flush it as appropriate before treatment.
  4. Introduce CorroGuard at a suitable feed point while water circulates, so the treatment mixes throughout the circuit.
  5. Test the specified inhibitor residual and water chemistry. Record corrosion indicators and microbial activity as part of the programme.
  6. Investigate changes in readings or makeup water demand, and adjust the programme with us when needed.

A Cooling Water Log Sheet can help keep test results and operating readings together for comparison.

Mistakes to avoid with cooling water treatment

  • Copying a dose from another product. Isothiazoline products and inhibitor blends can have different concentrations. Use the recommendation for CorroGuard and your system.
  • Adding chemicals without checking compatibility. Other biocides, inhibitors and glycol can affect the treatment programme. Tell us what is already in the water.
  • Leaving leaks or deposits untreated. Chemical addition does not repair a leak or remove the need to clean a fouled circuit.
  • Relying on microbiocide alone for tower hygiene. An open cooling tower needs a complete hygiene and Legionella control programme.

Safety, storage and MSDS

Keep CorroGuard in its labelled original container. Read the product MSDS for hazards, protective equipment, first aid, spill response, storage, segregation and disposal. Press "Get MSDS" at the top of this page to request it.

CorroGuard Cooling Water Antifoulant or another product?

We select the treatment programme around your system. Do not combine products until their compatibility and the required feed programme are established.

CorroGuard Cooling Water Antifoulant price and quotation in Oman

The price depends on the pack, quantity and delivery point. We keep CorroGuard in stock at Barka and will tell you the packs available. Send your quantity, preferred pack and delivery location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers get volume prices. We deliver from Barka to Muscat, Sohar, Salalah and Duqm.

Overview

RXSOL-40-4019 is a blend of superior quality low nitrite/molybdate based water treatment product developed specifically for closed circuit systems.RXSOL-40-4019 also contains isothiazoline.

Product description

Corrosion inhibitor with micro-biocide manufacturer and supplier for cooling water treatment. RXSOL-40-4019 is a blend of superior quality low nitrite/molybdate based water treatment product developed specifically for closed circuit systems. RXSOL-40-4019 Acrylic copolymer based advanced formulation with isothiazoline, Which is micro-biocide for industrial cooling water systems.  Isothiazolin is a preservative with antibacterial and antifungal effects, and is applicable at low concentration in all aqueous fluids.

Corrosion inhibitor Low nitrite / molybdate for closed circuits
 

Applications

CorroGuard is used for the control of corrosion and fouling in open recirculating cooling water systems.

Also known as

Accepta 2332, DREWGARD 180E, Corrosion inhibitor Antifoulant Biocide for Cooling System, PERFORMAX CL-4105,DREWSPERSE 739 VCT- 3500, MAXTREAT 7015

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.

Questions about CorroGuard Cooling Water Antifoulant

Who is the largest CorroGuard Cooling Water Antifoulant supplier in Oman?

Oman Chem is the largest CorroGuard Cooling Water Antifoulant supplier in Oman. We manufacture our own RXSOL formulation and keep it in stock at our Barka warehouse.

Can I use CorroGuard in an open cooling tower?

CorroGuard is listed for open recirculating cooling water as well as being developed for closed circuits. We will assess your tower and existing treatment programme before recommending it.

How much CorroGuard should I add to a closed chilled water loop?

The dose and dilution must be selected for your circuit. Send us the system volume, water analysis, metals and existing treatment details for a recommendation.

Can CorroGuard replace my existing corrosion inhibitor and biocide?

It may be suitable as part of a replacement programme, depending on your system and water chemistry. We will review the existing chemicals and monitoring requirements before a change.

What packs of CorroGuard can I buy in Oman?

We will tell you which packs are in stock when you send your requirement. Small and bulk orders can be quoted.

What is the price of CorroGuard Cooling Water Antifoulant in Oman?