Your One Stop for All Chemicals
Industrial • Marine • Cleaning
+968 9948 9269 / +968 9396 0629
WhatsApp / Call Us Anytime
omanchem.com@gmail.com
Drop Us a Line
Muscat, Sultanate of Oman
Locate Us

Boiler Chemicals-42

Mark Ship Chandler:
Educational Use Only - Order On Request

Boiler Water Treatment Autotreat

Product Code: RXSOL-50-5020-025

Product Short Description

Autotreat is a boiler water conditioner designed for optimum protection of boiler systems when used in conjunction with Oxygen Scavenger Plus. This well known phosphate treatment with new polymer technology. which helps to keep precipitates soft and no adherent for easy removal by blow down.

Other Equivalent Brand

BOILER WATER INHIBITOR, GREEN BWT, DM-532, OBWT-3, Autotreat 30 Kg Liquid

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

BWT MULTI PLUS 25 Ltrs

Product Code: RXSOL-50-5011-025

Product Short Description

Blend of New generation polymer, phosphate, and alkalinity booster to control scale and corrosion in the boiler.Water conditioner Multi Purpose BWT is multi-functional boiler water Treatment formulated to be used in conjunction with RXSOL OXYTREAT to provide a complete steam boiler with low hardne

Remarks

Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:

NaH2PO4 + NaOH -> Na2HPO4 + H2O
monosodium phosphate   sodium hydroxide   disodium phosphate   water


Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:

Na3PO4 + H2O -> Na2HPO4 + NaOH
trisodium phosphate   water   disodium phosphate   sodium hydroxide
 

 

Other Equivalent Brand

RXSOL Multiplus , Arboiler WT, DM-531, Optisperse Hp 5455 Phosphate Solution,BWT Liquid Plus

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

MULTIPLUS BWT 20 Ltrs

Product Code: RXSOL-50-5011-020

Product Short Description

Liquid Boiler water conditioner Blend of New generation polymer, phosphate, and alkalinity booster to control scale and corrosion in the boiler.

Remarks

Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:

NaH2PO4 + NaOH -> Na2HPO4 + H2O
monosodium phosphate   sodium hydroxide   disodium phosphate   water


Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:

Na3PO4 + H2O -> Na2HPO4 + NaOH
trisodium phosphate   water   disodium phosphate   sodium hydroxide
 

 

Other Equivalent Brand

RXSOL Multiplus, Arboiler WT, DM-531, Optisperse Hp 5455 Phosphate Solution

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Alkalinity Control

Product Code: RXSOL-50-5002-025

Product Short Description

Alkalinity Builder Very usefull Concentrated Alkaline Liquid For Maintaining Ph which protects corrosion, scalling by controlling Calcium scale in water system.

Remarks

The presence of alkalinity in a water sample may be due to many different substances.  However, for the sake of simplicity, the presence of bicarbonate, carbonate, and hydroxide ions is commonly considered as alkalinity.  The points of change in colour of phenolphthalein and methyl orange indicators, which occur at pH 8.3 and pH 4.3 provide standard reference points which are almost universally used to express alkalinity.

Very high alkalinity values can be undesirable in an industrial water supply.  For example, the presence of a high methyl orange alkalinity should be avoided in boiler feed water because of the resultant carbon dioxide content of the steam.  Carbon dioxide usually is responsible for the corrosion of steam and return lines.  High boiler water alkalinities are also undesirable because the presence of high hydroxide ion concentration is the primary cause of caustic metal embrittlement. A very high boiler alkalinity can also lead to an undesirable carryover condition.  On the other hand, the alkalinity of boiler water must be sufficiently high to protect the boiler metal against acidic corrosion and to ensure precipitation of scale-forming salts.  Usual treatment approaches include setting both a minimum alkalinity level and an operating range.
 

Hydroxide alkalinity may be determined by adding barium chloride prior to titration to precipitate the carbonate ion from solution, allowing direct titration of the hydroxide alkalinity.  Measurement of hydroxide alkalinity is also used to control lime soda softeners.
 

In cooling water systems, alkalinity is of major importance since the total alkalinity of a water is one factor that must be considered when predicting the tendency for the water to precipitate calcium carbonate scale.  Depending on the choice of chemical treatments to protect against corrosion and scale formation, the operating alkalinity and pH ranges are chosen to balance these two features.

 

Alkalinity Titrimetric Method (0-200 ppm) 

Principle Theory

This test is based on the determination of alkalinity by titration with standard acid to the phenolphthalein color change (or to a pH of 8.3) and to the methyl orange color change (or a pH of 4.3).  For determination of hydroxide alkalinity only, barium chloride is added prior to titration to precipitate the carbonate ions.  Titration is then taken only to the phenolphthalein end point.  A pH meter may be used instead of the indicators to determine the end points of the titration.

Other Equivalent Brand

GREEN AC, Alka Active Liquid, GC Concentrated Alkaline Liq, Alka Treat, ACT 100 NORCHEM, Alkaline Treatment Liquid 9-512, Eazy Neutralise, ALKATREAT, Nalco 77224, PH Neutraliser, Maxtreat-3004, Nalco 77222, Chem 3004- Alkali, DREW GC, INDION 1508, Chemical For Ph Alkalinity Indion-1508 Ion Exchange, Max Clean-05 Thermax, Nalco8940 Gr100, Alkanity Control 25 Ltr

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

One Shot Universal Liquitreat 100

Product Code: RXSOL-50-5001-025

Product Short Description

A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners

Remarks

Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce COin steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Other Equivalent Brand

RXSOL BWT LIQUID PLUS, Care Treat 3 Boiler 2, Drew Ameroid, Arboiler WT, BWT 104P Nor chem, B.W.T. NEW FORMULA EQUAL TO DREW - AGK 100, DM-511, EAZY BWT-1, MAXTREAT-3222, ONE SHOT BWT 25 Ltr, Liquitreat 25 Ltr, Maxgreen 3266, MAXTREAT 3333

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Sodium Tri Poly Phosphate STPP RXSOL

Product Code: RXSOL-19-1523-025

Product Short Description

STPP RXSOL

Other Equivalent Brand

STPP

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Condensnol Amine Evaporator Treatment

Product Code: RXSOL-50-5005-020

Product Short Description

LIQUID CONDENSATE CORROSION CONTROL FOR BOILER SYSTEMS

Remarks

RXSOL-50-5005-CC alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.

Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.

Packing. GENERAL REMARKS:-Do not store  RXSOL-50-5005-CA  near a heating equipment.

Other Equivalent Brand

GREEN CC, RXSOL 9-150 / SLCC-A, Care Treat-4, MARICHEM C.C.I.TM, Maxtreat 3330, DM-530, Condensate Control 20 Ltr,Condensate Control 20 Ltr

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

EDTA-Ethylene Diamine TetraAcetic Acid

Product Code: RXSOL-19-1519-025

Product Short Description

Disodium EDTA is a derivative of Ethylenediamine Tetraacetic Acid.

Remarks

Uses / Application of Disodium EDTA
Disodium EDTA is a Sequestering Agent, which is used in various Industries such as Pharmaceutical, Photography, Textile, Boiler Turbine scale removal, Agriculture. It is used for removing unwanted inorganic impurities present in the system, which helps in getting superior performance & cost saving.

Other Equivalent Brand

Ethylenediaminetetraacetic Acid Disodium Salt, N,N,1-2-ethanediylbis N-carboxymethyl glycine Edetic Acid Disodium Salt, Disodium Edetate, Metaclaw, Trilon B, Versene 220, Dissolvine, Titriplex, Dreplex OX, EDTA 25 Kg

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Diethyl Amino Ethanol

Product Code: RXSOL-19-1121-025

Product Short Description

2-DIETHYLAMINOETHANOL is an organic compound with amine and alcohol substituents.

Remarks

Never use DEAE in an open ventilation system, its oily residue can deposit on all available surfaces and results oil residue deposition. DEAE produces an oily residue which can soften varnishes.

Other Equivalent Brand

Diethylaminoethanol, DEAE, USED as O2 scavenger in boiler water, Not For Export

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Oxygen Controller Scavenger

Product Code: RXSOL-50-5023-025

Product Short Description

This is most common oxygen scavengers used to effectively remove dissolved OXYGEN from your feedwater.

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...