Boiler Chemicals

Mark Ship Chandler:

Sodium Sulphite sulfite with Catalyst Powder

Product Code: RXSOL-19-1305-025

Product Short Description

Removal of oxygen using commercial sodium sulfite and a catalyzed sodium sulfite makes great difference . After 25 seconds of contact catalyzed sodium sulfite removed the oxygen completely.

Remarks

Oxygen Control

Chemical Oxygen Scavengers. The oxygen scavengers most commonly used in boiler systems are sodium sulfite, sodium bisulfite, hydrazine, catalyzed versions of the sulfites and hydrazine, and organic oxygen scavengers, such as hydroquinone and ascorbate.

It is of critical importance to select and properly use the best chemical oxygen scavenger for a given system. Major factors that determine the best oxygen scavenger for a particular application include reaction speed, residence time in the system, operating temperature and pressure, and feedwater pH. Interferences with the scavenger/oxygen reaction, decomposition products, and reactions with metals in the system are also important factors. Other contributing factors include the use of feedwater for attemperation, the presence of economizers in the system, and the end use of the steam. Chemical oxygen scavengers should be fed to allow ample time for the scavenger/oxygen reaction to occur. The deaerator storage system and the feedwater storage tank are commonly used feed points.

In boilers operating below 1,000 psig, sodium sulfite and a concentrated liquid solution of catalyzed sodium bisulfite are the most commonly used materials for chemical deaeration due to low cost and ease of handling and testing. The oxygen scavenging property of sodium sulfite is illustrated by the following reaction:

2Na2SO3 + O2 ® 2Na2SO4
sodium sulfite   oxygen   sodium sulfate

 

Theoretically, 7.88 ppm of chemically pure sodium sulfite is required to remove 1.0 ppm of dissolved oxygen. However, due to the use of technical grades of sodium sulfite, combined with handling and blowdown losses during normal plant operation, approximately 10 lb of sodium sulfite per pound of oxygen is usually required. The concentration of excess sulfite maintained in the feedwater or boiler water also affects the sulfite requirement.

Sodium sulfite must be fed continuously for maximum oxygen removal. Usually, the most suitable point of application is the drop leg between the deaerator and the storage compartment. Where hot process softeners are followed by hot zeolite units, an additional feed is recommended at the filter effluent of the hot process units (prior to the zeolite softeners) to protect the ion exchange resin and softener shells.

As with any oxygen scavenging reaction, many factors affect the speed of the sulfite-oxygen reaction. These factors include temperature, pH, initial concentration of oxygen scavenger, initial concentration of dissolved oxygen, and catalytic or inhibiting effects. The most important factor is temperature. As temperature increases, reaction time decreases; in general, every 18°F increase in temperature doubles reaction speed. At temperatures of 212°F and above, the reaction is rapid. Overfeed of sodium sulfite also increases reaction rate. The reaction proceeds most rapidly at pH values in the range of 8.5-10.0.

Certain materials catalyze the oxygen-sulfite reaction. The most effective catalysts are the heavy metal cations with valences of two or more. Iron, copper, cobalt, nickel, and manganese are among the more effective catalysts.
 
Removal of oxygen using commercial sodium sulfite and a catalyzed sodium sulfite makes great difference. After 25 seconds of contact, catalyzed sodium sulfite removed the oxygen completely. Uncatalyzed sodium sulfite removed less than 50% of the oxygen in this same time period. In a boiler feedwater system, this could result in severe corrosive attack.

The following operational conditions necessitate the use of catalyzed sodium sulfite:

  • low feedwater temperature
  • incomplete mechanical deaeration
  • rapid reaction required to prevent pitting in the system
  • short residence time
  • use of economizers

High feedwater sulfite residuals and pH values above 8.5 should be maintained in the feedwater to help protect the economizer from oxygen attack.

Some natural waters contain materials that can inhibit the oxygen/sulfite reaction. For example, trace organic materials in a surface supply used for makeup water can reduce speed of scavenger/oxygen reaction time. The same problem can occur where contaminated condensate is used as a portion of the boiler feedwater. The organic materials complex metals (natural or formulated catalysts) and prevent them from increasing the rate of reaction.

Sodium sulfite must be fed where it will not contaminate feedwater to be used for attemporation or desuperheating. This prevents the addition of solids to the steam.

At operating pressures of 1,000 psig and higher, hydrazine or organic oxygen scavengers are normally used in place of sulfite. In these applications, the increased dissolved solids contributed by sodium sulfate (the product of the sodium sulfite-oxygen reaction) can become a significant problem. Also, sulfite decomposes in high-pressure boilers to form sulfur dioxide (SO2) and hydrogen sulfide (H2S). Both of these gases can cause corrosion in the return condensate system and have been reported to contribute to stress corrosion cracking in turbines. Hydrazine has been used for years as an oxygen scave

Other Equivalent Brand

Catalyzed sodium sulfite for corrosion prevention, Na2SO3

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

ComboTreat New Formula

Product Code: RXSOL-50-5004-020

Product Short Description

Well-balanced blend of several powder with antifoaming agent for boiler water treatment, resulting in a scale and corrosion control by one simple operation. It is applied to types of boiler water systems, providing excess protection from the hard, sl

Remarks

RXSOL-50-5004-020  is dependent on boiler operating condition, Feed 200 gm to 1 Kg  of RXSOL-50-5004-020 solution for per thousand Ltr of boilers water Then control  the  system by  Periodic Alkalinity  test procedure.  FREE LOGSHEET is available for our registered member. ( Maintaining of Logsheet allow to observing and evaluating the test results trend in order to use the exact amount needed for the stabilization of the system
If p-Alkalinity is below 200  ppm  increase the  ratio of  RXSOL-50-5004-020  solution. If  p-Alkalinity  is above  400 ppm  reduce  the  concentration of  RXSOL-50-5004-020  solution by dilution with water.          

RXSOL ALKALINITY, PHOSPHTE and SULFITE TEST KITS are available on request.

USES PROCEDURE : Always dissolve powder before feeding in BOILER WATER TANK.

                                                                                                                                             

Control Procedure:-

Control is by simple  boiler water tests or RX CLEANSERS  can provide a suitable test  kits for this purpose

Other Equivalent Brand

COMBITREAT powder 20 Kg

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Potable Water Stabilizer Liquid FRESH WATER

Product Code: RXSOL-51-6002-025

Product Short Description

The product effectively and economically provides scale and corrosion control in potable water and other shipboard once-through water systems. And specially designed to reduce the corrossion that is created in the storage systems of pot water.

Other Equivalent Brand

RXSOL - 624916 POTABLE WATER STABILIZER, chemo PWS, Caretreat PWT, Fresh Water Treatment. Potable Water Stabiliser Kit Liquid

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Sludge Conditoner for Boiler Water

Product Code: RXSOL-50-5010-020

Product Short Description

This high performance product is applicable to both medium and low-pressure steam boilers in order to prevent sludge deposits.

Other Equivalent Brand

DM-520

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

CAT Sulphite Sludge Conditioner

Product Code: RXSOL-50-5008-020

Product Short Description

Boiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed normal blow down. In this way tube over heating due to deposits is avoided.

Other Equivalent Brand

Boiler Sludge Conditioner Sulfite, MAXTREAT 3001

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

BIOCIDE MICRO for Water Treatment

Product Code: RXSOL-40-4009-020

Product Short Description

Strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water. Algae growth is the main cause of colour in water. Routine and weekly additions of RXSOL-40-4009-020 establish a buffer action

Remarks

Where MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 can be used?

For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. Add MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 at some point in the system to ensure uniform mixing.

Dose Ratio of 
MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 
NOTE: Badly fouled systems should be cleaned before treatment.
 
INITIAL DOSE: if the system is initiating fouling then use 200 ml - 3 ltr of  MICRO BIOCIDE Cooling Water RXSOL-40-4009-020  for per 3000 to 5000 Ltr of water in the system.) Dose can be increased till optimum results.
 
WEEKLY CONTROL DOSE: When microbial control is evident, add 100 to 500 ml per MICRO BIOCIDE Cooling Water RXSOL-40-4009-020  for per 3000 to 5000 Ltr of water in the system
 
AIR WASHER SYSTEMS : Add to the air washer sump or chill water sump to insure uniform mixing, 200 ml  - 3 Ltr of MICRO BIOCIDE Cooling Water RXSOL-40-4009-020  for per 3000 to 5000 Ltr of water in the system, DOSE ration directly proportional of  contamination to control microbial biofilms, bacteria, fungi, and algae which cause fouling in industrial air washer systems.
 


Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 for CONTINUOUS FEED METHOD  

Maintain this treatment level by adding a continuous feed of 100 ml to 1000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-020  per 1000 gallon of makeup water).

NOTE : Badly fouled systems must be cleaned before initial treatment.
 
 
 
Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-020 for INDUSTRIAL WASTEWATER TREATMENT SYSTEMS AND SEWAGE SYSTEMS

INITIAL DOSE for Noticeably Fouled Condition: 500 ml - 4000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-020  per 3000 Ltr of water in the system. Repeat until control is achieved. Badly fouled systems should be cleaned before treatment is begun.

SUBSEQUENT DOSE: When microbial control is evident, add 100 ml  - 100 ml MICRO BIOCIDE Cooling Water RXSOL-40-4009-020  per 3000 Ltr of water in the system.

Other Equivalent Brand

OXIDIZING BIOCIDE

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Oxygen Control Corrosion Inhibitor

Product Code: RXSOL-50-5007-025

Product Short Description

Catalyzed liquid oxygen scavenger, This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other harsh environments , f

Remarks

RXSOL-50-5007-025 is a powerful oxygen scavenger in liquid sulphite form suitable for low and medium pressure boilers. The reaction of RXSOL-50-5007-025 with oxygen is catalysed ensuring the rapid absorption of oxygen to protect feedlines and boilers from corrosion

Other Equivalent Brand

Oxygen ScaVenger, GREEN OC, Oxytreat-s, Eliminox 9-002, Eazy Safescav, Carbohydrazide Ox Scav Not Hydrazine, ROCHEM OXYTREAT, MAXTREAT 3100L, HYDRAZIDE, Aquatreat 660

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Soot Remover Powder

Product Code: RXSOL-70-7005-025

Product Short Description

Dry powder compound formulated for safe removal of soot and deposits from boilers and diesel engine exhaust systems.

Other Equivalent Brand

LT-Soot Release, Caretreat Soot, Soot Cleaner, Soot remover powder 25 Kg, Easy Soot remover-P, Rochemite Powder, LT SOOT RELEASE 25 kg

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Condensnol Amine Corrosion Control

Product Code: RXSOL-50-5005-025

Product Short Description

Concentrated Liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2

Remarks

RXSOL-50-5005-025 alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.

Other Equivalent Brand

Green CC, RXSOL 9-150 / SLCC-A, Care Treat-4, MARICHEM C.C.I.TM, CCT 102, Maxtreat 3330, DM-530, Condensate Treatment 9-150, BWT QC4, pH CONTROLLER AMINE base, NEUTRALIZING AMINE AGENT JCF 2005 RP-01A, BFW 85, NALCO 5711, Condensate Boiler Corrosion Control, Condensate Control 25 Ltr, MaxTreat 3311

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Toluene AR grade

Product Code: RXSOL-60-1201-500

Product Short Description

For Industrial, Pharmaceutical, Flavor & Fragrance or Lab Use. And For oil, water, Amine, Scale Composition tests metering operation

Remarks

Wear safety glasses. The working area must be well ventilated to prevent the build-up of toluene vapour. Make sure that any sources of ignition, such as Bunsen burners, hot plates and hot air guns, are removed before you start work.

Eye contact: Immediately flush the eye with plenty of water. Continue for at least ten minutes and call for medical help. Skin contact: Wash off with soap and water. Remove any contaminated clothing. If the skin reddens or appears damaged, call for medical aid. Note that clothes soaked in toluene will be very flammable, so should be removed in an area in which there is no risk that they might catch fire. If swallowed: Call for immediate medical help.

Other Equivalent Brand