Boiler Chemicals

Mark Ship Chandler:

Boiler Water Sludge Conditioner

Product Code: RXSOL-50-5010-025

Product Short Description

Product to be used in situations where the boiler water is contaminated with oil. This high performance product is applicable to both medium and low-pressure steam boilers in order to prevent sludge deposits.

Remarks

Our others valauable Products : 
BOILER TREAT ONE SHOT

Combined Boiler Water Conditioner

A one-product treatment for all auxiliary boilers including waste heat, and exhaust gas boilers. it prevents scale formation, inhibits corrosion and conditions sludge.

HARDNESS CONTROL
Boiler Water Conditioner

Added to the boiler water to maintain optimum phosphate level, which prevents calcium and magnesium hardness salts formation. The precipitate can be removed by blow-down.

ALKALINITY CONTROL
Boiler Water Conditioner 

Added to the boiler water to maintain optimum alkalinity level to prevent corrosion. Due to this, Ca and Mg hardness salts cannot form and the precipitate is removed by blow-down.

HYDRAZIDE
Oxygen Scavenger 
Used for rapid removal of oxygen in boiler feed water and condensate systems, which prevents corrosion. It is the alternative for hazardous and potentially carcinogenic products.

BOILER TREAT COMBI
Organic Boiler Water Treatment 
Special blended low molecular weight compounds that elevate boiler water pH to levels, which reduce corrosion. It also prevents under deposit corrosion caused by excess alkalinity.

LIQUID COAGULANT
Oil and Sludge Conditioner 

Used to prevent formation of adherent deposits and sticky sludge in boilers,which are then removed by normal blow-down. It can also be used in the event of an oil contamination.

CONDENSATE CONTROL
Steam and Condensate Conditioner 

Injected into the condensate pump to prevent corrosion in steam and condensate lines.It’s also used to protect idle boilers from corrosion. It neutralizes acidic conditions in condensate systems and volatilizes with steam.

COOL WATER TREAT NCLT
Corrosion and Scale Inhibitor 
Provides an effective anodic inhibitor treatment and protects ferrous and non-ferrous metals. It deposits a microscopic protective film on surfaces and has built-in pH buffering compounds. It controls formation of hard scale deposits.

EVEPORATOR TREAT
Prevention of scale in Evaporators
Used in both high and low pressure evaporators to prevent foaming, carry-over and scale formation. It’s safe to use where distillate is used for drinking purposes. It prevents scale formation and avoids the need for acid descaling.

Other Equivalent Brand

DM-520, BWT Conditioner, Coroban 30, MAXTREAT 3223, Boiler Water Sludge Conditoner 25 Ltr

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Boiler Coagulant Sludge Conditioner

Product Code: RXSOL-50-5003-025

Product Short Description

Boiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed by normal blowdown.

Remarks

RXSOL-50-5003-025 eliminate light oil contamination, A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilers. Boiler Coagulant  is a colorless, high molecular weight solution used in both medium and low-pressure boilers (<850 psig or 60 kg/cm2) 

Other Equivalent Brand

GREEN BC, Liquid Coagulant, LC 102/A ( Nor Chem ), 653-571331, Maxtreat 3221, Coagulant 25 Ltr

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

CAT Sulphite 25 Ltr

Product Code: RXSOL-50-5008-025

Product Short Description

Liquid sludge conditioner designed to prevent deposits.DOSES : The initial dosage is 20 ml of treatment daily for every ton of boiler capacity. Bottom blow down is required daily when using Boiler Coagulant.

Other Equivalent Brand

Nalco Catalysed Sulphite

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Hardness Phosphate Control

Product Code: RXSOL-50-5006-025

Product Short Description

Phosphate Boiler Water Treatment Hardness Control is a white dry powder Phosphate Boiler Water Treatment product is used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness

Remarks

Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:

NaH2PO4 + NaOH ® Na2HPO4 + H2O
monosodium phosphate   sodium hydroxide   disodium phosphate   water


Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:

Na3PO4 + H2O ® Na2HPO4 + NaOH
trisodium phosphate   water   disodium phosphate   sodium hydroxide
 

Other Equivalent Brand

Green HC, Phosphate Control Boiler Water Treatment Chemicals, HCT 103 Norchem, Ferrolix L40, Ferrolix L40A, DM-527, Fostreat, ADJUNCT Hardness Phosphate Control 25 Kgs Powder Pack

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Boiler Water Log Sheet

Product Code: RXSOL-50-5013-001

Product Short Description

Boiler Water Log Sheet

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Boiler Water Treatment Autotreat

Product Code: RXSOL-50-5020-025

Product Short Description

Autotreat is a boiler water conditioner designed for optimum protection of boiler systems when used in conjunction with Oxygen Scavenger Plus. This well known phosphate treatment with new polymer technology. which helps to keep precipitates soft and

Other Equivalent Brand

BOILER WATER INHIBITOR, GREEN BWT, DM-532, OBWT-3, Autotreat 30 Kg Liquid

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

BWT MULTI PLUS 25 Ltrs

Product Code: RXSOL-50-5011-025

Product Short Description

Blend of New generation polymer, phosphate, and alkalinity booster to control scale and corrosion in the boiler.Water conditioner Multi Purpose BWT is multi-functional boiler water Treatment formulated to be used in conjunction with RXSOL OXYTREAT

Remarks

Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:

NaH2PO4 + NaOH -> Na2HPO4 + H2O
monosodium phosphate   sodium hydroxide   disodium phosphate   water


Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:

Na3PO4 + H2O -> Na2HPO4 + NaOH
trisodium phosphate   water   disodium phosphate   sodium hydroxide
 

 

Other Equivalent Brand

RXSOL Multiplus , Arboiler WT, DM-531, Optisperse Hp 5455 Phosphate Solution,BWT Liquid Plus

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

MULTIPLUS BWT 20 Ltrs

Product Code: RXSOL-50-5011-020

Product Short Description

Liquid Boiler water conditioner Blend of New generation polymer, phosphate, and alkalinity booster to control scale and corrosion in the boiler.

Remarks

Phosphate/pH relationship recommended to control boiler corrosion. Different forms of phosphate consume or add caustic as the phosphate shifts to the proper form. For example, addition of monosodium phosphate consumes caustic as it reacts with caustic to form disodium phosphate in the boiler water according to the following reaction:

NaH2PO4 + NaOH -> Na2HPO4 + H2O
monosodium phosphate   sodium hydroxide   disodium phosphate   water


Conversely, addition of trisodium phosphate adds caustic, increasing boiler water pH:

Na3PO4 + H2O -> Na2HPO4 + NaOH
trisodium phosphate   water   disodium phosphate   sodium hydroxide
 

 

Other Equivalent Brand

RXSOL Multiplus, Arboiler WT, DM-531, Optisperse Hp 5455 Phosphate Solution

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Alkalinity Control

Product Code: RXSOL-50-5002-025

Product Short Description

Alkalinity Builder Very usefull Concentrated Alkaline Liquid For Maintaining Ph which protects corrosion, scalling by controlling Calcium scale in water system.

Remarks

The presence of alkalinity in a water sample may be due to many different substances.  However, for the sake of simplicity, the presence of bicarbonate, carbonate, and hydroxide ions is commonly considered as alkalinity.  The points of change in colour of phenolphthalein and methyl orange indicators, which occur at pH 8.3 and pH 4.3 provide standard reference points which are almost universally used to express alkalinity.

Very high alkalinity values can be undesirable in an industrial water supply.  For example, the presence of a high methyl orange alkalinity should be avoided in boiler feed water because of the resultant carbon dioxide content of the steam.  Carbon dioxide usually is responsible for the corrosion of steam and return lines.  High boiler water alkalinities are also undesirable because the presence of high hydroxide ion concentration is the primary cause of caustic metal embrittlement. A very high boiler alkalinity can also lead to an undesirable carryover condition.  On the other hand, the alkalinity of boiler water must be sufficiently high to protect the boiler metal against acidic corrosion and to ensure precipitation of scale-forming salts.  Usual treatment approaches include setting both a minimum alkalinity level and an operating range.
 

Hydroxide alkalinity may be determined by adding barium chloride prior to titration to precipitate the carbonate ion from solution, allowing direct titration of the hydroxide alkalinity.  Measurement of hydroxide alkalinity is also used to control lime soda softeners.
 

In cooling water systems, alkalinity is of major importance since the total alkalinity of a water is one factor that must be considered when predicting the tendency for the water to precipitate calcium carbonate scale.  Depending on the choice of chemical treatments to protect against corrosion and scale formation, the operating alkalinity and pH ranges are chosen to balance these two features.

 

Alkalinity Titrimetric Method (0-200 ppm) 

Principle Theory

This test is based on the determination of alkalinity by titration with standard acid to the phenolphthalein color change (or to a pH of 8.3) and to the methyl orange color change (or a pH of 4.3).  For determination of hydroxide alkalinity only, barium chloride is added prior to titration to precipitate the carbonate ions.  Titration is then taken only to the phenolphthalein end point.  A pH meter may be used instead of the indicators to determine the end points of the titration.

Other Equivalent Brand

GREEN AC, Alka Active Liquid, GC Concentrated Alkaline Liq, Alka Treat, ACT 100 NORCHEM, Alkaline Treatment Liquid 9-512, Eazy Neutralise, ALKATREAT, Nalco 77224, PH Neutraliser, Maxtreat-3004, Nalco 77222, Chem 3004- Alkali, DREW GC, INDION 1508, Chemical For Ph Alkalinity Indion-1508 Ion Exchange, Max Clean-05 Thermax, Nalco8940 Gr100, Alkanity Control 25 Ltr

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

One Shot Universal Liquitreat 100

Product Code: RXSOL-50-5001-025

Product Short Description

A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners

Remarks

Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce CO2 in steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Other Equivalent Brand

RXSOL BWT LIQUID PLUS, Care Treat 3 Boiler 2, Drew Ameroid, Arboiler WT, BWT 104P Nor chem, B.W.T. NEW FORMULA EQUAL TO DREW - AGK 100, DM-511, EAZY BWT-1, MAXTREAT-3222, ONE SHOT BWT, Liquitreat 25 Ltr, Maxgreen 3266, MAXTREAT 3333, AGK-100

Supply Locations