Tank cleaning instructions::
	
	In case PFAD is present, it is strongly recommended to start with a 1- 2% solution of Tankleen VO Rx . Heat the solution up to at least 60 °C and circulate for at least 2 full cleaning cycles. It is advised to rinse tanks and systems after the cleaning. Tankleen VO Rx is suitable to be used on epoxy coatings and stainless steel, it is not suitable to be used on zinc coated tanks.
	
	Consider the below for cleaning with Tankleen VO Rx is
	 
	- 
		The prewash, if performed, should always be done at a temperature of at least 15 °C higher than the melting point of the cargo.
- 
		The prewash, recirculation solution and hotwash can also be performed withseawater
- 
		Final rinse should be performed with fresh water to remove salt deposits
 
	A rule of thumb is to have for every 500m3 tank volume at least 1m3 of cleaning solution containing 2 - 3% Tankleen VO Rx . 
	Hardness stains– Tank cleaning
	Cleaning with 2% Tankleen VO Rx at a temperature of 60-70 oC to the tank wash machine.
	 DOSAGE
	Tank cleaning– PFAD & vegetable oil 2 - 4% solution or; In case of recirculation at least 30L per 500m3 tank volume.
	
	Hardness stains 2 % solution