Product code RXSOL-20-2047-210Category Tank Cleaner

Price and availability on request. Send us the quantity and delivery location in Oman.

Applications

Phenol (Cleaning Procedure)

Direct after discharge flush lines and tanks thoroughly with hot fresh water or demi water and recirculate. This is done to bring the freezing point down prior to the prescribed tank cleaning procedure. Demi water will be used if the pre-wash quantity can be pumped ashore.
 

  1. Butterworth the tanks 1, 5-2 hours with hot seawater or freshwater (80°C).
     
  2. Prepare the following cleaning solution in freshwater:0.4 % RXSOL CTC-VOLC
    Butterworth the tank 1 hour by recirculation with a temperature of approx 70°C. The
    necessary temperature can be achieved/maintained by means of heating
    coils, or 
    going via the Butterworth heater. The solution can be used for 1 to
     4 tanks.
     
  3. Butterworth the tank for 0, 5 hours with hot fresh water.
     
  4. Ventilate, mop and dry the tank.
  • Instead of recirculation cleaning the RXSOLCTC-VOLC can be as well injected into the Butterworth system (see cleaning method 3).

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah) and in India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), and we also supply to South Africa.