Product code RXSOL-40-5023-210Category Boiler Chemicals, Oxygen Scavengers

Price and availability on request. Send us the quantity and delivery location in Oman.

Oxygen Treat Scavanger PWD 25 Kg supplier and manufacturer in Oman

In short: Oxygen Treat Scavanger PWD 25 Kg is our RXSOL powdered oxygen scavenger for boiler feedwater. It is supplied as a powder for removing residual dissolved oxygen and reducing corrosion and pitting. We manufacture it, we are the largest Oxygen Treat Scavanger PWD 25 Kg supplier in Oman, and we keep it in stock at our Barka warehouse. The product is named for a 25 kg pack; our packing record also lists 50 kg polythene-lined bags, so we will confirm the pack available for your order. We deliver to Muscat, Sohar, Salalah and Duqm. Send us your quantity on WhatsApp for today's price.

When does boiler feedwater need an oxygen scavenger?

Dissolved oxygen attacks metal in boiler and feedwater systems. It can cause localised pitting in feed lines, closed heaters, economizers and boilers. RXSOL oxygen scavenger reacts with the oxygen left in feedwater after mechanical deaeration, helping protect those surfaces.

Check the treatment programme when dissolved oxygen is detected in feedwater or the deaerator is not performing properly. A sulfite residual below your programme's target is another reason to check the chemical feed, oxygen demand and test results. If pitting appears, investigate its cause as well as the oxygen treatment: corrosion can have more than one cause.

Oxygen scavenger powder dose for boiler feedwater

The estimated starting requirement is 10 ppm of powder for each 1 ppm of dissolved oxygen removed. This estimate allows for losses such as oxidation through contact with air and blowdown. It is a starting calculation, not a fixed dose for every boiler.

Feedwater conditionStarting calculationWhat to check
1 ppm dissolved oxygen to remove10 ppm of powderMeasured oxygen demand and the programme's sulfite residual
Oxygen demand changesRecalculate from the measured demandDeaerator performance, feed rate and residual
Residual below the programme targetReview the chemical feedOxygen ingress, sampling and test results

The treatment programme needs an excess sulfite residual for the reaction to proceed. Temperature and contact time also affect the reaction. Set the residual and operating feed rate for your boiler and its water treatment programme.

Step by step: dosing RXSOL oxygen scavenger powder

  1. Remove as much dissolved oxygen as practical with the mechanical deaerator.
  2. Measure dissolved oxygen in the feedwater and use the result to calculate the estimated starting requirement.
  3. Obtain the product technical bulletin and site-specific instructions for preparing the dosing solution. The product record does not specify a dilution strength.
  4. Feed the solution continuously into the boiler feedwater upstream of the boiler. This gives the reaction contact time and helps protect upstream equipment.
  5. Test the sulfite residual using a suitable test method. Adjust the feed to meet the treatment programme's specified residual and measured oxygen demand.
  6. Record the results and investigate changes in oxygen demand, residual or deaerator performance.

Mistakes to avoid with boiler oxygen treatment

  • Using powder as the only means of oxygen removal. Removing appreciable oxygen mechanically first can reduce chemical demand and cost.
  • Feeding straight into the boiler without considering the feed system. Upstream feed gives the scavenger more contact time and helps protect feed lines and associated equipment.
  • Assuming this grade is catalysed. The product record does not establish whether it is catalysed, so do not assume an instant reaction in cold water.
  • Using a fixed dose without testing. Oxygen demand can change, and the sulfite residual shows whether the feed is meeting the programme target.
  • Choosing treatment on dose alone. Boiler pressure, temperature, contact time, steam use and dissolved solids all matter. Sulfite treatment produces sulfate, which contributes to dissolved solids.
  • Relying on sulfite alone during shutdown. A boiler also needs a suitable shutdown and layup programme to limit oxygen corrosion.

Safety, storage and MSDS

The powder is mildly alkaline. Avoid swallowing it and take normal precautions when handling solid powders. Wash with water after contact. Store it dry, with the container tightly closed to limit contact with air. For protective equipment, first aid, incompatibilities and disposal, read the current product MSDS: press "Get MSDS" at the top of this page to request it.

Oxygen Treat Scavanger PWD 25 Kg or another product?

  • Residual oxygen in boiler feedwater: Oxygen Treat Scavanger PWD is our powdered treatment for use after practical mechanical deaeration.
  • A catalysed sulfite powder is specified: See Sodium Sulphite with Catalyst Powder. Select the grade for the system and its treatment programme.
  • A different oxygen scavenger chemistry is specified: Diethyl Hydroxyl Amine DEHA is another option where suitable for the boiler and steam use.
  • Hardness control is also needed: Hardness Control Boiler Treatment addresses a separate part of the boiler water programme.

Oxygen Treat Scavanger PWD 25 Kg price and quotation in Oman

The price depends on the pack, quantity and delivery point. The product is named for a 25 kg pack, and our record also lists 50 kg polythene-lined bags. We keep stock at Barka and will confirm the pack available for your order. Send your quantity, pack and delivery location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers get volume prices. We deliver from Barka to Muscat, Sohar, Salalah and Duqm.

Overview

This is most common oxygen scavengers used to effectively remove dissolved OXYGEN from your feedwater. Other grades of 5006 has its own advantages depending on your system and personal preferences

Product description

This is most common Oxygen Treatment Scavanger  used to effectively remove dissolved  OXYGEN from your feedwater. Other grades of 5006  has its own advantages depending on your system and personal preferences ) By the presence of dissolved oxygen in water system , corrosion and pitting caused on metal surface. RXSOL 5006 is a specially formulated and  powdered materials.  which, when added to boiler feedwater, removes dissolved oxygen , By acting as an Oxygen Treatment Scavanger.

Benefits:- By Control of corrosive oxygen from boiler water which causes corrosion and pitting ,It  improves boiler system long life and  reliability .

In boiler feedwater conditioning RXSOL-40-5023-210 is fed to a boiler to remove dissolved oxygen and thus prevent pitting. For the reaction between RXSOL-40-5023-210 and oxygen to proceed rapidly and completely, it is necessary to maintain an excess sulfite concentration at an elevated temperature. 

Applications

The use of RXSOL-40-5023-210 as a chemical deoxygenator is economical within certain limitations imposed by the dissolved oxygen content of the feedwater. If appreciable quantities of dissolved oxygen are permitted to enter the boiler, costs will be high if RXSOL-40-5023-210 is relied on as the sole means of oxygen removal. Generally, costs are balanced by removal of as much of the oxygen as feasible by mechanical means, e.g. deaerator and by using RXSOL-40-5023-210 to react with the residual oxygen.

To prevent corrosion and pitting in feed lines, closed heaters and economizers, it is desirable to feed the RXSOL-40-5023-210 continuously to the boiler feedwater rather than directly to the boiler feedwater rather than directly to the boiler. Reaction between RXSOL-40-5023-210 and oxygen is not instantaneous and the completion of the reaction is aided by the longer contact times provided by feeding RXSOL-40-5023-210 to the feedwater.

 

Catalyzed RXSOL-40-5023-210 will, however, react almost instantaneously with dissolved oxygen even at cold water temperatures. Because of this property, catalyzed RXSOL-40-5023-210 has found increased use in the treatment of cooling water, process water, distribution system, etc. for preventing oxygen corrosion.  

Dosage

Theoretically, 7.88 pounds of RXSOL-40-5023-210 are required to remove one pound of oxygen. The efficiency of the oxygen removal is estimated at 75 per cent to allow for oxidation in contact with air, blowdown losses, etc. Therefore it is estimated that 10 pounds of RXSOL-40-5023-210 are required for each pound of oxygen removed (or 10 ppm RXSOL-40-5023-210 per 1 ppm dissolved oxygen.)

Also known as

Maxtreat 3222, Oxygen Treat Scavanger PWD 25 Kg Powder, Maxtreat 3100, Oxygen Scavenger Powder form

Notes

TEST METHOD ::: http://rxmarine.com/hydrazine-test-kit

 

HANDLING, STORAGE AND PRECAUTIONS :

RXSOL-40-5023-210 is mildly alkaline in nature. Normal precautions should be taken while handling solid powders. In case of contact, wash with water. Do not swallow.

RXSOL-40-5023-210 should be stored in a dry condition. Close the container tightly to avoid contact with air.

PACKING :

RXSOL-40-5023-210 is available in 50 kg polythene lined bags.

Remarks

Oxygen Treatment Scavanger

Where we supply

Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.

Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.

Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.

Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.

Questions about Oxygen Treat Scavanger PWD 25 Kg

Who is the largest Oxygen Treat Scavanger PWD 25 Kg supplier in Oman?

Oman Chem is the largest Oxygen Treat Scavanger PWD 25 Kg supplier in Oman. We manufacture the RXSOL formulation and keep it in stock at our Barka warehouse.

What does an oxygen scavenger do in boiler feedwater?

It reacts with dissolved oxygen left in the feedwater, helping reduce oxygen corrosion and pitting in the boiler system.

Is this RXSOL oxygen scavenger powder catalysed?

The available product record does not establish whether this grade is catalysed or give its complete composition. We can provide the current product information for your review.

Where should the powder be dosed in a boiler system?

Feed the prepared solution continuously into the feedwater upstream of the boiler. This allows contact time and helps protect equipment before the boiler.

Can this powder be used in cooling water or a closed-loop system?

Some catalysed scavengers are used in these systems, but suitability of this particular grade must be established first. Give us the system details when requesting a recommendation.

What is the price of Oxygen Treat Scavanger PWD 25 Kg in Oman?

We quote each order by pack, quantity and delivery point. Send us your requirement for today's price.