Primary tabs

Educational Use Only - Order On Request
Corrosion Inhibitor for Citric Acid
Product Code: RXSOL-45-1503-005

Product Description

Inhibitor for Citric ACID

Citric Acid corrosion Inhibitor is an organic, liquid, cationic corrosion inhibitor especially designed to inhibit the attack of Citric Acid during industrial cleaning operations. It also inhibits acid attack on copper and brass. 

Product Short Description

Liquid Corrosion Inhibitor For Citric Acid, for Industrial Use

Product Application

The addition of Acid corrosion Inhibitor Citric Acid inhibitors to Citric acid solution provides maximum protection for equipment during:
A. The removal of lime deposits or water scale from power plant boilers and piping systems and from evaporating equipment.

B. The removal of scale and deposits from equipment in refineries, utility companies,paper mills, chemical plants and other industries.

Citric acid is a weak organic acid. It is a natural preservative/conservative and is also used to add an acidic, or sour, taste to foods and soft drinks. In biochemistry, the conjugate base of citric acid, citrate, is important as an intermediate in the citric acid cycle, and therefore occurs in the metabolism of virtually all living things.

Product Dose

For each For each 1000ltrs of pickling bath Citric Acid Inhibitor must be added at the rate of 1 to 5ltrs (1.1 - 5.7kgs)* Citric  acid solution, not less than the following amount of Citric Acid corrosion Inhibitor should be used:

The dosage varies with the bath temperature as follows:
Up to 65 C - 1ltr (1.1kg)
65°C - 80°C - 3ltrs (3.4kg)
80°C - 90°C - 4ltrs (4.6kg)
90 - 100°C - 5ltrs (5.7kg)

The exceptional strength and heat stability of Citric Acid corrosion Inhibitor give the user a considerable safety factor in relation to temperature, acid strength, and time. Citric Acid corrosion Inhibitor  may be added to either the diluted or concentrated Citric acid Solution. In either case, Citric Acid corrosion Inhibitor  should be thoroughly mixed with the acid by stirring or agitation.

The hydrochloric acid solution inhibited with Citric Acid corrosion Inhibitor  is best circulated through the equipment to be cleaned. When circulation cannot be accomplished, the equipment should be filled with the inhibited acid and allowed to react for sufficient time to remove the objectionable deposits. To estimate the proper acid concentration and cleaning time, samples of the deposits to be removed can be tested in the laboratory prior to cleaning. If heating of the equipment to be cleaned or acid solution is desired to speed the cleaning action, it should be done prior to the start of the cleaning operation
 

Description:
For replenishment of bath with concentrated pickling acid, Citric Acid Corrosion Inhibitor should be dosed at the rate of 0.6 to 2.3kgs (0.5 to 2.0ltrs) per 100kgs of concentrated pickling acid.
Citric Acid Corrosion Inhibitor is completely effective up to the following maximum temperatures:
In Citric acid - max.60°C

Product Note

Storage and Disposal

Citric Acid Corrosion Inhibitor and will not freeze at temperature as low as -20° Fahrenheit. Below 0° Fahrenheit, Citric Acid Corrosion Inhibitor become very viscous and may be difficult to pump. It is recommended that Citric Acid Corrosion Inhibitor  be stored in a dry area where the temperature will not go lower than 0° Fahrenheit.

Applicable regulations concerning disposal and discharge of chemicals should be consulted and followed-

Disposal information for Citric Acid Corrosion Inhibitor is given on the Material Safety Data Sheet for each product.The industrial cleaning bath is acidic and contains Citric acid and organic Citric Acid Corrosion Inhibitor  components. Waste treatment , neutralization is required. The industrial cleaning bath and sludge can contain ingredients other than those in the chemical as supplied and analysis of the solution and/or sludge is required before waste treatment and disposal.

Safety and Handling :

Before handling the chemical products used in this process, the first aid and handling recommendations on the Material Safety Data Sheet for should be read, understood and followed. The industrial cleaning bath is strongly acid and can burn skin and eyes. Refer to the Material Safety Data Sheet for hydrochloric acid for recommendations for protective action.

Industrial area

When Acid like hydrochloric acid is used in system, it is needless to say that equipment can be protected without uses of Acid corrosion inhibitor.
 
Acid corrosion Inhibitor RXSOL 213 containing chelatig agent, acidic blend of complex alkyl pyridines, 1, 3, diethyl thiourea and many more to protects steel, brass and copper against the attack of acid. 
 
Can be use as single product for multiple acids, Easily soluble with all acid concentrations

Acid Corrosion inhibitor manufacturer. exporter and supplier in India Kuwait, UAE, Oman, Mumbai Maharastra, Chennai Tamilnadu, Kolkata WestBengal, Visakhapatnam Andhrapradesh, Gandhidham Surat Gujrat, Fujairah Dubai Sharjah Ajman Abudhabi, Oman Muscat Sohar, Canada, Nairobi Kenya Africa

Remarks

Acids and corrosive materials are used to enhance production and to stimulate reservoirs therefore special care is required to ensure that casing, tubing strings and downhole equipment are not damaged. Blend of ACID with Citric Acid Corrosion Inhibitor protect your downhole equipment and metal tubulars.

Product Tag Identification

Citric Acid Corrosion Inhibitor have chemical properties of sequestration, deflocculation, threshold inhibition and hydrolytic stability etc. Citric Acid Corrosion Inhibitor also act as an organophosphoric acid corrosion inhibitor. It can chelate with Fe, Cu, and Zn ions to form stable chelating compounds. It can dissolve the oxidized materials on these metals’ surfaces.

Product Useful Area

Citric Acid Corrosion Inhibitor also resulting good corrosion and antiscaling effect. 

It's good resistance towards High and Low pH value makes it unique and better than that of other organophosphoric acids (salt). 
Citric Acid Corrosion Inhibitor also resulting high chlorine oxidation tolerance properties.

Citric Acid Corrosion Inhibitor has good antiscale and visible threshold effects. 

Free Delivery / Supply Locations

Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...