Price and availability on request. Send us the quantity and delivery location in Oman.
CORROSION INHIBITOR CI 3023 supplier and manufacturer in Oman
In short: CORROSION INHIBITOR CI 3023 is our own RXSOL film-forming corrosion inhibitor for oil and gas production and pipelines. We manufacture and supply it in industrial drums and bulk packs for internal corrosion control. We are the largest CORROSION INHIBITOR CI 3023 supplier in Oman and keep it in stock at our Barka warehouse. We deliver to Muscat, Sohar, Salalah and Duqm. Send us your quantity on WhatsApp for today's price.
When does an oil or gas pipeline need corrosion treatment?
Water in contact with pipeline steel can cause internal corrosion. Dissolved gases, salts and operating conditions affect how quickly the metal deteriorates. Review the corrosion management programme when you see:
- Corrosion coupon or probe readings rising over time.
- Wall loss, pitting or corrosion-related damage found during inspection.
- A change in water cut, salinity or dissolved gases in the production fluid.
- A change in temperature or flow that could affect corrosion or inhibitor distribution.
CI 3023 adsorbs onto compatible metal surfaces and forms a protective film. The film reduces contact between the metal and corrosive production fluids. Continuous injection can replenish it as fluid flows through the system.
CI 3023 for oilfield and pipeline corrosion in Oman
| Your situation | How CI 3023 is used | What to establish |
|---|---|---|
| Crude oil pipeline or gathering line | Continuous injection into the transported fluid | Distribution to the surfaces needing protection and a dose supported by corrosion measurements |
| Oil and gas production line or flowline | Continuous treatment of compatible metal surfaces | Fluid composition, water cut, metallurgy and operating conditions |
| Production equipment or industrial hydrocarbon system | Film-forming corrosion control where suitable | Compatibility and performance under the actual operating conditions |
| Batch treatment or initial film establishment | Site-specific treatment programme | Method and dose validated for the system |
For continuous pipeline injection, the published preliminary range is 6 to 12 ppm. Use it as a starting range for laboratory and field trials. The effective rate depends on the fluid, temperature, flow and metallurgy.
Step by step: dosing CI 3023 into a pipeline
- Analyse the production fluid, including water cut, salinity, dissolved gases and other corrosive constituents.
- Identify the pipeline metallurgy, operating temperature and flow conditions.
- Test CI 3023 with representative fluids and production chemicals. Assess corrosion control, emulsion tendency and film performance.
- Select an injection point that distributes the inhibitor to the surfaces needing protection.
- Establish a preliminary treatment rate through laboratory testing and field trials. State whether the ppm target is by mass or volume and which fluid phase it covers.
- Calculate the pump setting from the actual fluid flow and inhibitor density. Inject continuously with a calibrated chemical dosing pump.
- Monitor corrosion using coupons, electrical resistance probes or other approved methods. Adjust the injection rate according to the results.
For example, a line carrying 100 m³ per hour at 10 ppm by mass needs about 1 kg of inhibitor per hour if the fluid density is 1,000 kg/m³. The required injection volume depends on the inhibitor density. No dilution ratio is established for CI 3023; test the proposed diluent and mixture before use.
Mistakes to avoid with pipeline corrosion inhibitor
- Using the starting dose as a fixed dose. Measure corrosion performance and adjust treatment for the line.
- Mixing up the ppm basis. A mass-based target and a volume-based pump calculation need the correct densities and fluid flow.
- Assuming the film reaches the whole line. Injection location, flow and deposits affect distribution.
- Skipping compatibility tests. Crude oil, produced water and other chemicals can affect inhibitor performance and fluid separation. Test CI 3023 alongside products such as Demulsifier Premium where both are used.
- Assuming sour service or acidizing suitability. Test fluids containing hydrogen sulfide or carbon dioxide under representative conditions. Concentrated acidizing fluids need a separately tested acid inhibitor.
Safety, storage and MSDS
Wear chemical-resistant gloves, eye protection and protective clothing. Keep the product away from heat and ignition sources and work with good ventilation. Store containers tightly closed and properly labelled in a cool, dry, well-ventilated location.
Read the current finished-product MSDS for the supplied batch before use. Press "Get MSDS" at the top of this page to request it.
CORROSION INHIBITOR CI 3023 or another product?
- Internal corrosion in compatible oil and gas pipelines and production lines: CI 3023. It is listed as an alternative to KI 3939. Compare the original product documents and test performance before substitution; the listing does not mean the formulations are identical.
- Another oil and gas processing application: consider Corrosion Inhibitor for Oil and Gas Processing. Select the treatment against the fluid and operating conditions.
- Hydrogen sulfide in the production system: a Hydrogen Sulfide Scavenger may be considered as part of the treatment programme. It does not automatically replace a corrosion inhibitor.
CORROSION INHIBITOR CI 3023 price and quotation in Oman
The price depends on the pack, quantity and delivery point. We keep CI 3023 in stock at Barka; industrial drum and bulk pack availability is confirmed with your quotation. To buy, send your quantity, pack and location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers get volume prices. We deliver from Barka to Muscat, Sohar, Salalah and Duqm.
Overview
Film-forming corrosion inhibitors work by adsorbing onto metal surfaces and forming a protective barrier that reduces contact between corrosive fluids and the underlying metal.
Product description
RXSOL Corrosion Inhibitor CI 3023 is a film-forming corrosion inhibitor
The product is intended to reduce internal corrosion of compatible metallic surfaces in oil and gas production and pipeline transportation systems.
Film-forming corrosion inhibitors work by adsorbing onto metal surfaces and forming a protective barrier that reduces contact between corrosive fluids and the underlying metal.
RXSOL Corrosion Inhibitor CI 3023, code RXSOL-81-8165-211.
THINK CHEMICAL THINK RXMARINE
Applications
RXSOL TECHNICAL PRODUCT BULLETIN
CORROSION INHIBITOR KI 3939
Film-Forming Corrosion Inhibitor for Oil & Gas Production and Pipeline Protection
RXSOL Equivalent Product: Corrosion Inhibitor CI 3023 RXSOL Product Code: RXSOL-81-8165-211 Product Category: Oilfield Chemicals / Pipeline Corrosion Inhibitors Application: Oil & Gas Production, Hydrocarbon Pipelines and Industrial Corrosion Protection
Major Applications
|
Application |
Purpose |
|---|---|
|
Crude Oil Pipelines |
Internal corrosion protection |
|
Oil & Gas Production Lines |
Control of corrosion in production fluids |
|
Flowlines |
Protection of compatible carbon steel surfaces |
|
Gathering Pipelines |
Corrosion management during fluid transportation |
|
Production Equipment |
Reduction of corrosion-related metal deterioration |
|
Industrial Hydrocarbon Systems |
Corrosion control where validated |
Suitability for CO₂-containing or H₂S-containing fluids must be confirmed through representative corrosion testing. Inhibitor performance depends on fluid composition, temperature, flow conditions and metallurgy.
Industries and related products
Frequently Asked Questions
Q1. What is the RXSOL equivalent of Corrosion Inhibitor KI 3939?
RXSOL identifies Corrosion Inhibitor CI 3023 (RXSOL-81-8165-211) as an alternative product. This is a catalogue cross-reference, not proof of identical formulation.
Q2. What is the main application of KI 3939?
The RXSOL-listed alternative is intended for film-forming corrosion protection in oil and gas pipeline systems.
Q3. What is the recommended dosage?
The published range is 6–12 ppm, but actual dosage must be validated under field operating conditions.
Q4. Can it protect against CO₂ and H₂S corrosion?
Potentially, depending on the formulation. Performance under sweet or sour service conditions must be verified through representative testing.
Q5. Is KI 3939 suitable for acidizing?
The available RXSOL cross-reference does not establish suitability for concentrated acidizing fluids. Acid corrosion inhibitors require separate testing for acid strength, temperature, exposure time and metallurgy.
Dosage
Working Mechanism
The intended corrosion inhibition mechanism involves:
Surface Adsorption: Active inhibitor components adsorb onto compatible metal surfaces.
Protective Film Formation: A barrier film reduces exposure of the metal to corrosive components.
Corrosion Rate Reduction: The protective layer helps reduce electrochemical corrosion reactions.
Film Maintenance: Continuous injection may be required to replenish the inhibitor film under flowing conditions.
Recommended Dosage
|
Application |
Preliminary Dosage |
|---|---|
|
Continuous Pipeline Injection |
6–12 ppm, supplier-published range |
|
High-Corrosion Systems |
Determine through laboratory and field trials |
|
Initial Film Establishment |
Site-specific treatment programme |
|
Batch Treatment |
Subject to system design and validation |
Example: For a pipeline carrying 100 m³/hour of fluid, a treatment rate of 10 ppm by mass corresponds to approximately 1 kg/hour of inhibitor if the treated fluid density is assumed to be 1,000 kg/m³.
For other fluid densities, the required inhibitor mass flow changes accordingly.
The actual injection volume also depends on the inhibitor's density.
Also known as
KI 3939 Corrosion Inhibitor 25 Ltr
Notes
Recommended Application Procedure
-
Analyse the production fluid, including water cut, salinity, dissolved gases and other corrosive constituents.
-
Confirm pipeline metallurgy and operating temperature.
-
Select a suitable chemical injection point.
-
Establish the preliminary dosage through laboratory testing.
-
Inject continuously using a calibrated chemical dosing pump.
-
Monitor corrosion performance using coupons, electrical resistance probes or other approved techniques.
-
Adjust the injection rate according to measured corrosion performance.
Remarks
Performance Evaluation
Recommended tests include:
-
Corrosion coupon weight-loss testing.
-
Electrochemical corrosion testing.
-
Compatibility with crude oil and produced water.
-
Emulsion tendency assessment.
-
Thermal stability testing.
-
Film persistency testing.
-
Dynamic flow-loop testing where appropriate.
-
Compatibility with demulsifiers, scale inhibitors and other production chemicals.
Storage & Handling
Store in tightly closed, properly labelled containers in a cool, dry, well-ventilated location.
Use appropriate chemical-resistant gloves, eye protection and protective clothing.
Follow the finished-product SDS for handling, transport classification, fire precautions and spill response.
Packing
Product Code: RXSOL-81-8165-211
Industrial drum and bulk packing availability should be confirmed when requesting a quotation.
Where we supply
Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.
Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.
Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.
Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.
Questions about CORROSION INHIBITOR CI 3023
Who is the largest CORROSION INHIBITOR CI 3023 supplier in Oman?
Oman Chem is the largest CORROSION INHIBITOR CI 3023 supplier in Oman. We manufacture our own RXSOL formulation and keep it in stock at our Barka warehouse.
What is CI 3023 used for in oil and gas pipelines?
It forms a protective film on compatible metal surfaces to reduce internal corrosion from production fluids. It is intended for pipelines, flowlines, gathering lines and production equipment.
What dose of CI 3023 should I start with?
The published preliminary range for continuous pipeline injection is 6 to 12 ppm. Laboratory and field results determine the rate needed for your system.
Is CI 3023 equivalent to KI 3939?
RXSOL lists CI 3023 as an alternative to KI 3939. The catalogue cross-reference does not prove identical formulation or field performance, so compare the product documents and test the replacement.
Can CI 3023 be used in fluids containing carbon dioxide or hydrogen sulfide?
It may be suitable, but performance must be established using representative fluids, metallurgy and operating conditions. Suitability for concentrated acidizing fluids is not established.
What is the price of CORROSION INHIBITOR CI 3023 in Oman?
We quote each order according to pack, quantity and delivery point. Send your requirement by WhatsApp or through the quote form for today's price.






