Price and availability on request. Send us the quantity and delivery location in Oman.
BOILPLEX AT Hardness Control supplier and manufacturer in Oman
In short: BOILPLEX AT Hardness Control is our own RXSOL boiler water treatment, a liquid blend of phosphates and synthetic polymers. It controls hardness scale, keeps sludge soft and helps manage alkalinity in low and medium pressure boilers. We manufacture it, keep it in stock at our Barka warehouse, and we are the largest BOILPLEX AT Hardness Control supplier in Oman. It is used on marine auxiliary and exhaust gas boilers, process steam boilers and plant boilers fed with variable water. We deliver to Muscat, Sohar, Salalah and Duqm in 25 L cans, 210 L drums and 1000 L IBCs. Send us your quantity on WhatsApp for today's price.
When does a boiler need BOILPLEX AT?
Your boiler water tests usually show the problem before the tubes do:
- Hardness shows up in the feedwater, or the makeup water quality changes from day to day.
- Phosphate, alkalinity or conductivity in the boiler water drift outside your control range.
- Sludge builds up at the bottom of the boiler and the blowdown comes out heavy and dirty.
- Scale or hard deposits appear on heating surfaces at inspection.
- Condensate pH runs low and the return lines start to corrode.
Hardness that is not treated bakes onto tubes as scale. Scale cuts heat transfer, wastes fuel and can lead to overheated tubes and costly acid cleaning.
How BOILPLEX AT works in marine and industrial boilers
BOILPLEX AT combines phosphates, synthetic polymers, alkalinity control agents and deposit conditioning additives. Each part has a job:
- Phosphates react with calcium and magnesium hardness and turn it into a precipitate instead of hard scale. They also help disperse iron.
- Polymers coat the precipitate so the particles stay soft, loose and non-adherent. This mobile sludge leaves the boiler with routine blowdown.
- Alkalinity control holds the boiler water in its working range and helps protect the condensate side from low pH corrosion.
This makes BOILPLEX AT tolerant of unstable feedwater. It suits ships where condensate return and makeup quality vary, and plants with changing feed conditions.
Where to dose BOILPLEX AT
| Your system | Feed point | Notes |
|---|---|---|
| Dosing pump, feedwater recirculation fitted | Recirculation outlet, below where cascade water returns to the tank | Preferred set-up. Steady, continuous feed. |
| Dosing pump, no feedwater recirculation | Suction line of the boiler feed pump | Keep the feed continuous through the day. |
| Gravity dispenser only | Feed water tank or cascade tank | Supply line about 1 metre above normal water level, close to the feed pump. Less preferred, as product can be lost when water returns to the cascade. |
Step by step: dosing BOILPLEX AT
- Find the total boiler water volume and the operating pressure.
- Test the feedwater for hardness, conductivity, pH and alkalinity.
- Dissolve BOILPLEX AT in distilled water or clean condensate in the dosing tank.
- Feed it continuously over 24 hours through a calibrated dosing pump at the feed point above.
- Test the boiler water every day and adjust the daily dose to the results.
- Blow down as set by your control programme and log each test so you can see the trend.
The daily amount depends on system volume, condensate purity and the quality and quantity of the feedwater. Poor feedwater needs more product and more blowdown. We set the starting dose and daily rate for your boiler from your water analysis.
Testing and blowdown with BOILPLEX AT
Control BOILPLEX AT with simple boiler water tests: hydrate alkalinity, conductivity, phosphate, feedwater hardness and condensate pH. Blowdown removes the conditioned sludge and the dissolved and suspended solids. Regular blowdown keeps conductivity at about 700 µmho. Above 700 µmho, blow down more often. Where the boiler has a steam collector or separator, flush it weekly to stop sludge collecting there.
Mistakes to avoid
- Dosing in slugs. Batch doses let the residual swing. BOILPLEX AT works best fed continuously.
- Skipping blowdown. The polymers keep sludge soft, but it still has to leave the boiler.
- Relying on it for oxygen control. BOILPLEX AT is not an oxygen scavenger. Run a separate scavenger in the programme.
- Mixing it with dirty water. Dissolve it in distilled water or condensate, not raw makeup water.
- Ignoring feedwater quality. Treatment does not replace good feedwater. Distilled feed is the best defence against deposits.
- Expecting it to strip old hard scale. It prevents new scale and conditions sludge. Heavy existing scale needs a descaling job first.
Safety, storage and MSDS
Handle BOILPLEX AT concentrate with chemical-resistant gloves and eye protection, as with any concentrated boiler treatment. Rinse splashes off skin and eyes with plenty of fresh water. Keep containers closed and upright in a shaded store, away from food and drinking water. Read the MSDS before use: press "Get MSDS" at the top of this page to request it.
BOILPLEX AT Hardness Control or another product?
- Hardness, scale and sludge control in low and medium pressure boilers: BOILPLEX AT.
- Dissolved oxygen in the feedwater: add an oxygen scavenger such as Oxygen Remover Scavanger Plus alongside BOILPLEX AT.
- Carbonic acid corrosion in steam and condensate lines: Condensnol Amine Corrosion Control.
- Boiler water alkalinity running low: top up with Alkalinity Control.
- Extra sludge dispersion with very dirty feed: Sludge Conditoner for Boiler Water. Send us your boiler water results and we tell you which mix fits.
BOILPLEX AT Hardness Control price and quotation in Oman
The price of BOILPLEX AT Hardness Control depends on the pack, the quantity and the delivery point, so we quote every order. It is in stock at our Barka warehouse in 25 L cans, 210 L drums and 1000 L IBCs. Send the quantity, the pack and the delivery location on WhatsApp +968 7733 3599 or through the quote form. Bulk and wholesale buyers, ship chandlers and plant operators get volume prices. We deliver from Barka to Muscat, Sohar, Salalah, Duqm and to ships at Port Sultan Qaboos, Sohar Port, Salalah Port and Duqm.
Overview
In addition to controlling the alkali content, scale and sediment, Boilplex ATprotects the condensate system (Steam superheater) from corrosion caused by low pH. Boilplex AT control sludge and sediment deposition by adsorption on sludge boiler surfac
Product description
RXSOL BOILPLEX AT – Advanced Boiler Water Treatment Chemical
Phosphate–Polymer Boiler Treatment | Scale Inhibitor | Sludge Conditioner | Corrosion Control
Product Name: BOILPLEX AT Hardness Control
Product Code: RXSOL-40-5027-025
Brand: RXSOL
Category: Marine & Industrial Boiler Water Treatment
Reference Product: DREWPLEX AT by Drew Marine
RXSOL already lists BOILPLEX AT Hardness Control (RXSOL-40-5027-025) as its phosphate–polymer boiler treatment product for applications similar to DREWPLEX AT.
THINK RXMARINE
BOILPLEX AT Hardness Control is specialized Boiler Water treatment product to KEEP Boiler water Clear and Clean SLUDGE FREE.
Boilplex AT is basically phosphates combination with synthetic polymers. Very easy to use, provides flexibility in system operation and control over the operation of the auxiliary and exhaust gas heaters on the boats. The tool is designed to maintain the cleanliness of the boiler at unstable as feedwater.
Applications
Product Description
RXSOL BOILPLEX AT is a multipurpose boiler water treatment chemical based on a combination of phosphates, synthetic polymers, alkalinity-control agents and deposit-conditioning additives.
The product is designed to control hardness-related scale, sludge formation and corrosion in low- and medium-pressure marine and industrial boiler systems.
RXSOL BOILPLEX AT helps maintain boiler cleanliness by conditioning hardness precipitates and suspended impurities, preventing their firm adhesion to heat-transfer surfaces. Its polymeric dispersants assist in maintaining soft, mobile sludge that can be removed through routine boiler blowdown.
The treatment is particularly useful in boiler systems experiencing variations in feedwater quality, condensate return conditions and makeup water composition.
When used as part of a complete boiler treatment program with an appropriate oxygen scavenger, RXSOL BOILPLEX AT supports reliable boiler operation, improved heat-transfer performance and reduced deposit-related maintenance.
To be most effective to prevent corrosion and scaling using drug Boilplex AT the drug should be constantly adding to the boiler system with a dosing devices BWT Dosing System. Less preferable to use gravitational dosing device, because preparation can evaporate when the water returns into the tank cascade.
Where it is used
RXSOL BOILPLEX AT Hardness Control Sludge Conditioner most commonly used in low and medium pressure boilers, to keep BOILER WATER CLEAR and Sludge free.
Technical Specifications
|
Parameter |
RXSOL Specification / Description |
|---|---|
|
Appearance |
Clear liquid |
|
Specific Gravity at 25°C |
1.056 (published RXSOL value) |
|
Chemical Base |
Phosphate and synthetic polymer blend |
|
Physical Form |
Liquid |
|
Water Compatibility |
Intended for aqueous dosing |
|
Primary Function |
Hardness, scale and sludge control |
|
Secondary Function |
Alkalinity and corrosion management |
|
Standard Packing |
25 L |
The appearance and specific gravity are taken from the published RXSOL product listing. Other quantitative properties, including pH, phosphate concentration and active polymer content, require batch-specific confirmation.
RXSOL – Manufacturer & Supplier
Boiler Water Treatment Mechanism
1. Hardness Control
Phosphate compounds react with residual calcium hardness to form less adherent precipitates that can be conditioned and removed through blowdown.
2. Polymer Dispersion
Synthetic polymers help disperse suspended particles, iron oxides and hardness precipitates, reducing deposit accumulation on boiler heating surfaces.
3. Scale Prevention
The combination of phosphate treatment and polymeric deposit control helps limit hard scale formation and associated heat-transfer losses.
4. Alkalinity Management
Alkalinity-control ingredients maintain suitable boiler water conditions, reducing the risk of certain forms of internal corrosion.
5. Condensate Protection
Where the verified formulation includes an appropriate volatile neutralizing amine, it may also support condensate system pH control.
Recommended Companion Treatment
RXSOL BOILPLEX AT should be used with an appropriate oxygen scavenger where required by the boiler treatment program.
Suitable treatment technologies may include DEHA-based, catalyzed sulphite or other approved oxygen-scavenging systems, selected according to boiler pressure, steam application and water quality.
BOILPLEX AT should not be assumed to remove dissolved oxygen on its own.
Product Details
|
Field |
Details |
|---|---|
|
RXSOL Product Title |
BOILPLEX AT Boiler Water Treatment Chemical – RXSOL |
|
RXSOL Description |
RXSOL BOILPLEX AT RXSOL-40-5027-025 is a phosphate-polymer boiler treatment for scale prevention, sludge conditioning and marine boiler maintenance. |
|
RXSOL Product |
|
|
Boiler Water Focus |
BOILPLEX AT Boiler Water Treatment |
|
Product |
Phosphate Polymer Boiler Treatment, Marine Boiler Scale Inhibitor, Boiler Sludge Conditioner, Boiler Water Treatment Supplier |
|
Product |
RXSOL BOILPLEX AT phosphate polymer boiler water treatment chemical 25 litre |
RXSOL BOILPLEX AT should be presented as an independently branded product for similar applications.
Industries and related products
Boiler Water Treatment Polymer based new generation Chemicals for Hardness control.
BOILPLEX AT – Hardness Control
BOILPLEX AT is a specially formulated boiler water treatment chemical designed to control hardness-forming salts and prevent scale formation in boiler systems. It helps maintain efficient heat transfer, protect boiler surfaces, and support reliable boiler operation.
Key Benefits:
-
Controls calcium and magnesium hardness
-
Helps prevent scale formation on boiler heating surfaces
-
Reduces the risk of hard deposits and sludge accumulation
-
Supports efficient heat transfer
-
Helps improve boiler operating efficiency
-
Assists in protecting boiler systems from deposit-related problems
-
Suitable for routine boiler water treatment programs
Applications:
Industrial Boilers, Marine Boilers, Steam Boilers, Hot Water Boilers, and other boiler water treatment systems.
BOILPLEX AT is a boiler water treatment solution developed for hardness control and deposit prevention. Regular use helps maintain cleaner boiler surfaces and contributes to efficient and reliable boiler operation.
Suggested Product Title:
BOILPLEX AT – Advanced Boiler Hardness & Scale Control Treatment
Dosage
Recommended Dosage and Application
Initial Treatment
For reference, the original DREWPLEX AT manufacturer recommends an initial treatment of 2.5–5 litres per metric tonne of boiler system water. This is a reference-product dosage, not a verified RXSOL BOILPLEX AT dosage.
Actual RXSOL dosing should be determined from its active concentration, boiler water analysis, system volume and operating conditions.
Continuous Dosing Procedure
-
Determine the total boiler water volume and operating pressure.
-
Check feedwater quality, hardness, conductivity, pH and alkalinity.
-
Prepare the treatment solution using suitable clean condensate or demineralized water, where approved.
-
Dose continuously through a calibrated chemical dosing pump into the designated feedwater line.
-
Monitor boiler water alkalinity, phosphate, conductivity and condensate quality.
-
Adjust treatment dosage and blowdown according to the approved control program.
Regularly enter solutions drugs Boilplex AT with a dosing device BWT Dosing System in feedwater recirculation outlet below which returns cascading water in the tank. If there is no recirculation of feedwater, the drug should be submitted in suction tube feeding pump. When using gravity dispenser the drug should be fed to the point of feed water tank or in cascade. Drug supply line should be higher than normal water level (about 1 meter) and as close as possible to the fence of water nutrient pump. Boilplex AT to be dissolved in distilled water or condensate in the dispensing tank and gradually continuously fed for 24 hours, keeping the system demand. The daily dosage is depend on the volume of the system, the condensate quality and purity, as well as the quality and quantity of the feed water system. For standard operating systems the dosage Boilplex AT is about 1 liter a day.
Very large systems or in non-standard conditions will have a greater need for preparation. Many factors can affect the initial dose of the drug. The two most important factors - quality feedwater and the boiler. The recommended initial dose of 2.5 to 5 liters per tonne of water system. After the initial filling of the product during operation of the system on a daily basis should perform a test to adjust the dosage. Low quality feedwater demands increase quantities of preparation, as well as leaching of the polluted water from the boiler of the boiler due to the settling of particles on bottom of the boiler during system shutdown. This in turn entails the need for additional purging and increase the amount of drug.
The main objective of the program - to prevent fouling. The most effective way to fight c deposits is to use distilled water feed. Boilplex AT created for removing water hardness instability.
Blowdown
Purge procedure is necessary for the effectiveness of any treatment program and boiler watershall be in accordance recommendations manufacturer's instructions. Purging is required to remove the precipitate dissolved and suspended solids. Normal regular purging with sufficient neutral of conductivity 700 μmho. A higher rate of conductivity (above 700 μmho) frequency blowdown should be increased. Additionally, it is recommended to wash weekly collector or separator pair (if any) to reduce the accumulation of sludge.
Also known as
DREWPLEX AT-10, Boiler Sludge Controller
Notes
Testing:
Dosage and frequency Boilplex AT controlled blowdown simple tests on the quality of the boiler water.Tests include checking parameters such as hydrate alkalinity, conductivity, phosphates, stiffness feedwater and condensate pH. For more information about the testing procedure, refer to Table control the amount and dosage Boilplex AT Control and Dosage Chart or contact representative of Rx Marine International.
CHARACTERISTICS :
- Has dispersant properties.
- Converts crystals.
- Comprehensive protection.
- Air conditioning sludge.
- Multi-tool.
- Prevents scale.
- Easy to use and testing.
BENEFITS
- Do not allow the particles to stick together.
- Do not allow the build-up of scale on pipes.
- Provides efficient heat transfer.
- Soft sludge" can be easily removed by blowing.
- Redundant components ensure protection.
- Boiler Cleaner.
- Increases in operation.
- Reduces the need for acid peels.
- Saves maintenance costs Kotel.
- Control of corrosion caused due to low.
- pH levels in the condensate system.
- Controls alkalinity.
- Controls the formation of a new scale.
- Convenient for operator.
Remarks
Did you know, how to keep BOILER water CLEAR and Sludge free?
RXSOL BOILPLEX AT Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure Boilers which results in the clean boiler water. USES of RXSOL BOILPLEX AT Hardness Control provide tolerance of feedwater quality fluctuations.
Chemically one part of The polymers used in BOILPLEX AT keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during boiler cleaning and maintenance operation.
While Other part of Phosphate which is used in BOILPLEX AT serve as deposit control agents by Iron dispersancy, main cause of sequestering deposits.
USES of RXSOL BOILPLEX AT boiler water treatment, can help BOILER WATER CLEAN and CLEAR.
Frequently Asked Questions
Q1. What is RXSOL BOILPLEX AT used for?
It is a multipurpose boiler water treatment chemical designed for hardness control, scale prevention, sludge conditioning and alkalinity management.
Q2. Is RXSOL BOILPLEX AT an alternative to DREWPLEX AT?
RXSOL markets BOILPLEX AT for a similar phosphate–polymer boiler treatment application. Direct equivalence requires comparative formulation and performance testing.
Q3. Can BOILPLEX AT be used in marine auxiliary boilers?
Yes, subject to the boiler manufacturer's recommendations, operating pressure and verified RXSOL treatment specifications.
Q4. Does BOILPLEX AT prevent boiler scale?
Its phosphate and polymer treatment approach is intended to reduce hardness-related deposits and help prevent adherent scale.
Q5. Does BOILPLEX AT contain an oxygen scavenger?
Oxygen-scavenging performance has not been established for this RXSOL formulation. A separate approved oxygen scavenger should be used when required.
Q6. What is the recommended dosage?
Dosage depends on the actual product concentration, boiler volume, makeup water quality and boiler water test results. The reference DREWPLEX AT initial dosage is 2.5–5 L/tonne, but this must not be automatically transferred to RXSOL.
Q7. Can BOILPLEX AT be used in food-processing boilers?
Only if the actual RXSOL formulation has the necessary approvals for the intended steam-contact application. The NSF registrations of DREWPLEX AT do not apply automatically to RXSOL.
Where we supply
Oman. Stocked at our warehouse in Barka, South Al Batinah, and supplied to Muscat, Ruwi, Mutrah, Seeb, Rusayl, Barka, Sohar, Shinas, Saham, Buraimi, Nizwa, Ibri, Sur, Salalah, Duqm, Khasab and every other governorate.
Ports and free zones. Port Sultan Qaboos (Mutrah), Mina Al Fahal, Sohar Port and Freezone, Port of Salalah and Salalah Free Zone, Port of Duqm and the Duqm Special Economic Zone, Port of Sur, Khasab Port and Al Mazunah Free Zone.
Industrial areas. Rusayl, Sohar, Barka (Sanaya), Raysut (Salalah), Nizwa, Sur, Buraimi and Duqm industrial estates, Knowledge Oasis Muscat, and oil and gas sites across Oman.
Beyond Oman. We have branches in the UAE (including Fujairah), India (Kandla, Kolkata, Visakhapatnam, Chennai and Mumbai), Kenya (Nairobi) and Canada, and we also supply to South Africa.
Questions about BOILPLEX AT Hardness Control
Who is the largest BOILPLEX AT Hardness Control supplier in Oman?
Oman Chem (Muscat & Barka for Business Trading) is the largest BOILPLEX AT Hardness Control supplier in Oman. We manufacture this RXSOL boiler treatment ourselves and keep it in stock at our Barka warehouse.
Is BOILPLEX AT suitable for marine auxiliary and exhaust gas boilers?
Yes. It is made for low and medium pressure marine and industrial boilers, including auxiliary and exhaust gas boilers on ships.
Does BOILPLEX AT contain an oxygen scavenger?
No oxygen scavenging effect is claimed for BOILPLEX AT. Use a separate oxygen scavenger in the same treatment programme.
Is BOILPLEX AT an alternative to DREWPLEX AT?
BOILPLEX AT is our phosphate and polymer treatment for the same kind of duty as DREWPLEX AT. We do not claim the formulas are identical, so we set the BOILPLEX AT dose from your own boiler water tests.
Will BOILPLEX AT reduce acid cleaning?
Yes. By stopping new scale and keeping sludge soft enough to blow down, it reduces the need for acid descaling and cuts maintenance costs.
What is the price of BOILPLEX AT Hardness Control in Oman?
We quote each order by pack, quantity and delivery point. Send your requirement on WhatsApp +968 7733 3599 or through the quote form for today's price.