Boiler Chemicals-42

Mark Ship Chandler:
Educational Use Only - Order On Request

Scale Remover 1507

Product Code: RXSOL-42-1008-0025

Product Short Description

Scale dissolver. Specifically formulated to remove rust and water scale build up from boiler evaporators, heat exchangers, cooling systems, pipeline collection system etc. Highly effective on heating. Safe and easy handling and storage.

Remarks

-   Prevent run off water from entering drains if possible

Formation of Calcium Sulfate is main cause for SCALE formation :::

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.  

Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Other Equivalent Brand

INDION 1507 Colour Indicator Scale Remover Liquid

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Sodium Hydroxide 48

Product Code: RXSOL-42-1308-030

Product Short Description

Sodium Hydroxide Liquid General Use: Drinking water treatment, papermaking and other manufacturing applications, Detergent and soap industries etc.

Other Equivalent Brand

NaOH 48%, Caustic Soda Liquid

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Aqua Soft Water Softener

Product Code: RXSOL-42-4049-025

Product Short Description

Water Softener regeneration product for ion exchange softeners that removes hardness forming calcium and magnesium. It prevents scale, improves heat transfer and protects boilers and pipelines.

Other Equivalent Brand

Aqua Treat 100, Boiler Water Softener, Boiler Water Conditioner

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

FRESH WATER GENERATOR TREATMENT

Product Code: RXSOL-42-6001-025

Product Short Description

Neutral Liquid for prevention of scale in seawater Evaporators

Remarks

RXSOL-51-6001-025 is a concentrated  solution of a POLYELECTROLYTE  polymer and Antifoaming Agents for  use in SEA WATER evaporator  as a controller of scale and foam in side the  evaporators.  It can be used as a scale inhibitor  in the  feed water  to EVAPORATORS producing fresh water .

A liquid polymer-based evaporator treatment specially designed to control and prevent scale formation in evaporators

Other Equivalent Brand

FWG Treatment Chemical, Fresh Water Generator Evaporator Treatment

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Oxygen Scavenger Carbohydrazide

Product Code: RXSOL-42-2541-210

Product Short Description

No oxygen is entering the boiler with the feed water when hydrazine is present in the water ( This will help to decrease oxygen on HP, LP boiler )

Remarks

Carbohydrazide is used as an oxygen scavenger for high pressure boilers in power plants and other industries to reduce corrosion of metal pipes and fittings.

What is CarboHydrazide ?
Carbohydrazide the hydrazide of carbonic acid.


Why Hydrazine is replace by Carbohydrazide ?
Carbohydrazide (CH6N4O) - RXSOL-42-2541-025 is an oxygen scavenger often added to boiler systems to control corrosion. It reacts with oxygen at low temperatures and pressures. It also passivates metal surfaces preventing further corrosion. The reaction products are volatile, so they do not contribute to dissolved solids in the system. Carbohydrazide is widely used to replace hydrazine as an oxygen scavenger because it is less toxic.

Other Equivalent Brand

Nalco Eliminox, Carbohydrazide Based Oxygen Scavenger

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

Condenser Coil Cleaner

Product Code: RXSOL-42-5015-005

Product Short Description

It is a specially engineered condenser coil cleaner and brightener. this product is recommended for use in hotels, commercial complexes, hospitals, shipyards and any air-conditioning workshops or establishments that services air conditioning systems.

Remarks


This product is avilable with all our associated ship chandlers of INDIA and Middle East by product code no RXSOL-16-1028-025.

we are manufactrer of RXSOL-16-1028-025 , and supplier in kakinada, Visakhapatnam, Vizag, Mumbai, Goa, Surat, Gandhidham, Kandla, Mundra, Chennai, Ennore, Kolkata, Haldia, Pirpav, Fujairah, Dubai, Sharjah, Abu Dhabi and Gulf.

RXSOL brand Aluminium Cleaner exporter for TURKEY, Australia.

Other Equivalent Brand

Condensor Coil Cleaner Red 5 ltrs

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

AQUATEX 6460

Product Code: RXSOL-42-4029-035

Product Short Description

Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.

Other Equivalent Brand

AQUATREAT 6460

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

CHEMZOL 941

Product Code: RXSOL-42-4029-050

Product Short Description

Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.

Remarks

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Other Equivalent Brand

Chemsol 941

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

CHEMZOL 9200

Product Code: RXSOL-42-1524-050

Product Short Description

Extremely suitable oxygen scavenger for low and medium pressure boilers.

Remarks

The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.

Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.

The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.

The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation

It is used to arrest oxygen in sea water

It removes Entrapped Oxygen and thus reduces Corrosion

In Oil Drilling Chemicals

Other Equivalent Brand

Chemsol 9200

Supply Locations

Muscat, Salalah, Sohar, Duqm, Rustaq, Barka, Sanaiya, Sur, Seeb, Shinas, Nizwa, Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Fujairah, Sharjah, Umm Al Quwain, Ruwais, Khalifa Port, Jebel Ali, DP WORLD, and all UAE ports...

Educational Use Only - Order On Request

CorroSOL 66 Corrosion Scale Inhibitor Boiler

Product Code: RXSOL-42-4029-030

Product Short Description

Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.

Remarks

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.