REAGENT & APPARATUS |
|
Reagent: RXSOL TK 7 , TK 8 , TK 9 , . Apparatus : TEST TUBE , Titrator or DROPPER |
|
A.) PROCEDURE for p-ALKALINITY test ( STEP WISE ) |
|
1 |
Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
|
|
2 |
Add 1-2 drops of RXSOL TK7 and mix with the stirring rod , If sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rdstep otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) .
|
|
3 |
Add RXSOL TK9 drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 25 ppm of p-Alkalinity , expressed as CaCO3
|
|
RESULT |
Each DROPS is equivalent to 25 PPM of p-Alkalinity. |
|
NOTE |
p-Alkalinity VALUE = 25 X ( Total Number of DROPS of TK9 , during 3rdstep ) |
|
B.) PROCEDURE for m-ALKALINITY test ( STEP WISE )
1.1 >> Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
1.2 >> Add 2-3 drops of RXSOL TK8 and mix with stirring rod , the sample will turn to BLUISH-GREEN .
1.3 >> AddRXSOL TK9 carefully by counting drop by drop and mixing throughly until a light reddish (salmon) pink colour develop.
RESULT : Each DROPS is equivalent to 25 PPM of m- Alkalinity
m-Alkalinity VALUE = 25 X ( Total Number of DROPS of TK9 , during 1.3 step )
|
|
C.) PROCEDURE for TOTAL ALKALINITY ( VALUE of A + VALUE of B ) |
|
2.1 |
Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
|
|
2.2 |
Add 1-2 drops of RXSOL TK7 and mix with the stirring rod , If sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rdstep otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) then proceed to STEP- 4.
|
|
2.3 |
Add RXSOL TK9 drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 15 ppm of p-Alkalinity , expressed as CaCO3
|
|
2.4 |
Add 2-3 drops of RXSOL TK8 and mix with stirring rod , the sample will turn to BLUISH-GREEN . |
|
2.5 |
AddRXSOL TK9 carefully by counting drop by drop and mixing throughly until a light reddish ( salmon ) pink colour develop.
|
|
RESULT |
Each DROPS is equivalent to 25 PPM of Alkalinity |
|
NOTE |
p-Alkalinity ppm CaCO3VALUE = 25 X ( Total Number of DROPS of TK9 , during 2.3 step ) = X ( Say )
m-Alkalinity ppm CaCO3VALUE = 25 X ( Total Number of DROPS of TK9 , during 2.5 step ) = Y ( Say )
Total Alkalinity ppm CaCO3VALUE = X+Y
|
|
|
|
NUMBER OF DROPS OF TK9 |
|
p-Alkalinity as CaCO3 |
|
1 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
25 |
|
2 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
50 |
|
3 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
75 |
|
4 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
100 |
|
5 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
125 |
|
10 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
250 |
|
20 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
500 |
|
30 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
750 |
|
40 |
>>>>>>>>>>>>>>>>>>>>>>>>>> |
1000 |
Optimum Result : p-Alkalinity level is between 100 to 150 PPM is suggested.
if p-Alkalinity level is more then 150 ppm then level should be reduced by increased BLOW DOWN process with immediate effect.
For Below 50 ppm , Dose ½ Ltrs of RXSOL-50-5001-BWT for 1000 Ltrs of BOILER WATER , to maintain p-Alkalinity level 100 ppm.
Refill pack : REPLACEMENTS
TK7 : ECONOMIC PACK ( 100 / 200 / 500 ml ) available
TK8 : ECONOMIC PACK ( 100 / 200 / 500 ml ) available
TK9 : ECONOMIC PACK ( 100 / 200 / 500 ml ) available
|