Nitrite Test Kit

Product Code ::RXSOL-62-5507-001
Product Short Description: Nitrites are useful as corrosion inhibitors, preservatives, pigments, and in manufacturing many organic preservative chemicals. A Maximum Contaminant Level of 1 mg/L has been established by the USEPA for nitrite-nitrogen in drinking water.
Remarks:
Other Equivalent Brand:

Cooling Water Test Kit , jcwt test, Caretreat 2 Diesel, Cool water Treat Corrosion Inhibitor Al Test Kit, COOLING WATER TITRATE, Nalcool Test Kit

Images: Alt

Keyword:

TIPS for estimation of Total Dissolved solids in water:


Requirements: Glass and plastic beaker Spirit lamp

Funnel and filter paper Boiling chips

Procedure:

. Filter the sample water.

. Weigh the glass beaker W1 g

. Take 50 mL of sample water in the glass beaker.

. Evaporate the water carefully until the glass beaker becomes dry.

. Cool and weigh the glass beaker with the boiling chips again, W2 g.

Calculation: Total solid (ppm) = (W1 – W2) x 2 x 104 Filterable residue:

Procedure:

. Weigh the empty glass beaker with boiling chips, W1 g.

. Filter the sample water into a plastic beaker.

. Pour 50 mL of filtered water into the glass beaker.

. Evaporate the water carefully until the glass beaker becomes dry.

. Cool and weigh the glass beaker with the boiling chips again, W2 g.

Calculation:

Filterable residue (ppm) (W2 – W1) x 2 x 104
Non-filterable residue (ppm) = total solid – filterable residue.

packaing_size:

Nitrite Test Kit manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Nitrite Test Kit at a competitive price from us. We have ready stock of Nitrite Test Kit in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates



Hydrazine Test Kit Colorimetric Procedure

Product Code ::RXSOL-62-5524-001
Product Short Description: Distinct yellow colour test
Remarks:

Before Sampling all PRECAUTION should be taken :::

Toxic effects of Hydrazine ( which is collected in sample ) is a severe skin and mucous membrane irritant in humans; in animals.In humans, the vapor is immediately irritating to the nose and throat and causes dizziness and nausea; itching, burning, and swelling of the eyes develop over a period of several hours. Severe exposures of the eyes to the vapors causes temporary blindness lasting for about 24 hours. Recurrent exposure to hydrazine hydrate has been reported to cause contact dermatitis of the hands without systemic intoxication. In humans, hydrazine is absorbed through the skin, by inhalation, and orally; systemic effects include weight loss, weakness, vomiting, excited behavior, and convulsions; the chief histologic findings are fatty degeneration of the liver and nephritis. 

Images: Alt

Keyword:

 

Interfering Substance

Interference Level   

Ammonia 

No interference up to 10 mg/L. May cause a positive interference of up to 20% at 20 mg/L.      

Highly colored or turbid samples

Prepare a 1:1 mixture of deionized water and household bleach. Add one drop of this mixture to 25 mL of sample in a graduated mixing cylinder and invert to mix. This will destroy any hydrazine in the sample. Use this solution, instead of deionized water, to prepare the blank in the test procedure.

 

Morpholine No interference up to 10 mg/L.

packaing_size:

Where Hydrazine Test Kit used ?

HYDRAZINE TEST KIT is used for the determination of Hydrazine content in the Boiler’s Water. The test must be performed when in the vessel’s Boiler Water Treatment used hydrazine ingredient to control rust and corrosion RXSOL-50-5022-025 / RXSOL-50-5007-025 / RXSOL-19-1541-025. This is an activated hydrazine solution (Hydrazine with a catalyst for faster reaction with Dissolved Oxygen,) and applied for marine and industrial Boilers in low, medium and high pressures. 

Benefit of Hydrazine Test Kit ?

Following the procedure above, the concentration in ppm of Hydrazine in the Boiler Water will be obtained. According to the Boiler’s working conditions, and the results obtained the dosage of Oxygen Scavenger / Hydrazine must be adjusted considering the dose chart. For effective boiler water treatment with Hydrazine and in order to avoid any problem of Oxygen corrosion, the test at the initial period of use of RXSOL Oxygen Scavenger must be performed every day. Once a small concentration of Hydrazine obtained in the Boiler water then the test could be repeated every 2–3 days.

Limitation of Hydrazine Dose ?

Control of Hydarazine level in Boiler water is very important.  As proper level maintenance protect metal machinery parts from corrosion, However, precautions must be taken to prevent excess dose of hydrazine chemical as excess hydrazine will begin to decompose at temperature above 200oC to form Ammonia.

Hydrazine is one of popular an alternative Oxygen Scavenger. It is very important to protect boiler components from feed boiler water corrosion. 

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates



Chloride Test Kit

Product Code ::RXSOL-62-5506-001
Product Short Description: Determination of Chloride ppm value
Remarks:


REAGENT & APPARATUS:
Reagent:  RXSOL TK 1 , TK 2 , TK 3 , TK4 . Apparatus : TEST TUBE , Titrator or DROPPER.

VIDEO Help :  
https://www.youtube.com/watch?v=p_IgKoO49iE

Images: Alt

Keyword:

Best suitable product for Boiling & Cooling testing applications in marine shipping and Industrial system. Control of CHLORIDE ion is very important in the instrument as Chloride ion corrode all contact precious metal parts of machinery and circulation pipeline.

packaing_size:

Calculations

The constant weight of the crucible = a g
The constant weight of the crucible AgCl = b g 

Weight of  AgCl = (b – a ) g 
Now AgCl ( 143.34 )  = Cl-  35.46 ) = NaCl ( 58.46 )

Here Simple Calculation is :  143.34 g of AgCl = 35.46 g of chloride

(b–a)gofAgCl = 35.46/143.34x(b–a)g of chloride or 25 ml of the given solution contains

= 35.46/143.34 ( b – a ) g of chloride  

Amount of Cl
- ion present in one liter of the solution

= 35.46/143.34 x( b – a )x1000/25
= 35.46 x( b – a ) x40 / 143.34 g

 

Similarly, the strength of NaCl solution in g/liter of the solution
= 58.46 x( b – a ) x 40 / 143.34 g 

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Boiler Water Test Kit 310

Product Code ::RXSOL-62-5501-001
Product Short Description: Boiler Water Test Kit 310
Remarks:
Other Equivalent Brand:

TEST KITS & REAGENT, SPECTRPACK 310, PH-CHLORIDE-HARDNESS-ALKALINITE-PHOSPHATE, BOILER WATER TEST KIT

Images: Alt

Keyword:

packaing_size:

Boiler Water Test Kit 310 manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Boiler Water Test Kit 310 at a competitive price from us. We have ready stock of Boiler Water Test Kit 310 in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Cooling Water Test kit RXSOL 309

Product Code ::RXSOL-62-5508-001
Product Short Description: REAGENT:-NITRITE, CHLORIDE , pH, ALKALINITY
Remarks:
Other Equivalent Brand:

Test Kit and Chemical DEWT, PH-CHLORIDE-NITRITE-HARDNESS,COOLING WATER TEST KIT, Spectrapak 309 Cooling Water Test Kit,JACKET WATER TESTING KIT

Images: Alt

Keyword:

REAGENT:-NITRITE, CHLORIDE , pH, ALKALINITY

packaing_size:

Cooling Water Test kit RXSOL 309 manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Cooling Water Test kit RXSOL 309 at a competitive price from us. We have ready stock of Cooling Water Test kit RXSOL 309 in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Test Tube Stand for 50 Ml Stainless Steel

Product Code ::RXSOL-21-2120-001
Product Short Description: Anti Rust chemical resistance Stainless Steel stand
Remarks:
Other Equivalent Brand:

Anti Rust chemical resistance Stainless Steel stand

Images: Alt

Keyword:

packaing_size:

Test Tube Stand for 50 Ml Stainless Steel manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Test Tube Stand for 50 Ml Stainless Steel at a competitive price from us. We have ready stock of Test Tube Stand for 50 Ml Stainless Steel in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates